Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
- 1 June 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 26 (6) , 1081-1088
- https://doi.org/10.1097/00003246-199806000-00032
Abstract
To perform a functional evaluation of five different high-frequency, oscillatory-type ventilators that are currently being marketed for neonatal high-frequency oscillation. Observational animal study. Laboratory. New Zealand White male rabbits. Oscillator waveforms and delivered volumes were measured plethysmographically for the following ventilators: the SensorMedics 3100 A; the Drager Baby Log 8000; the Metran Humming V; the Infant Star; and the Infant Star 950. The independent variables which were adjusted included frequency (5 to 15 Hz), amplitude (25% to 100%), mean airway pressure (5 to 25 cm H2 O) and lung injury. At 15 Hz, the volume delivered at the 100% amplitude setting varied from 2.1 to 8.8 mL. Generally, the delivered volume decreased with increasing frequency, and with increased percentage of amplitude. Volume delivery was relatively unaffected by mean airway pressure but decreased with lung injury. Waveforms ranged from pure sinusoidal to a complex square wave. The handling of inspiration/expiration time ratios was ventilator specific. The SensorMedics inspiration/expiration ratio is user selected over a range from 1:2.3 (30% inspiratory time) to 1:1 (50% inspiratory time) and once selected it is consistent over its entire range of operating frequencies. The Drager ratio is machine determined and varied from 1:2.5 at 5 Hz to 1:1 at 15 Hz. Inspiratory time of the Infant Star is machine set at 18 msecs such that the inspiration/expiration ratio is 1:10.1 at 5 Hz and 1:2.7 at 15 Hz. The Humming V has a fixed inspiration/expiration ratio of 1:1. The relationship of the mean airway pressure displayed on the ventilator to the alveolar occlusion pressure varled considerably among devices. The displayed mean pressure could either overestimate (SensorMedics at 33% inspiratory time or Infant Star), approximate (Humming V), or underestimate (Drager) the mean lung distending pressure measured during a brief occlusion maneuver. The findings demonstrate large variations in machine performance. The ventilators also differed profoundly in complexity of operation and versatility as neonatal ventilators. (Crit Care Med 1998; 26:1081-1088)Keywords
This publication has 26 references indexed in Scilit:
- High frequency oscillation in newborn infants with respiratory failureJournal of Paediatrics and Child Health, 1995
- Preoperative stabilization using high-frequency oscillatory ventilation in the management of congenital diaphragmatic herniaCritical Care Medicine, 1994
- Understanding the pressure cost of ventilation: Why does high-frequency ventilation work?Critical Care Medicine, 1994
- Volume recruitment maneuvers are less deleterious than persistent low lung volumes in the atelectasisprone rabbit lung during high-frequency oscillationCritical Care Medicine, 1993
- Mechanisms of ventilator-induced lung injuryCritical Care Medicine, 1993
- Proximal, Tracheal, and Alveolar Pressures during High-Frequency Oscillatory Ventilation in a Normal Rabbit ModelPediatric Research, 1990
- Role of lung volume in lung injury: HFO in the atelectasis-prone lungActa Anaesthesiologica Scandinavica, 1989
- Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.Journal of Clinical Investigation, 1983
- Effects of frequency, tidal volume, and lung volume on CO2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation.Journal of Clinical Investigation, 1981
- In Vivo Lung Lavage as an Experimental Model of the Respiratory Distress SyndromeActa Anaesthesiologica Scandinavica, 1980