Comparison of fluorescent and colorigenic substrates for enzyme immunoassays
- 1 May 1982
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 15 (5) , 757-760
- https://doi.org/10.1128/jcm.15.5.757-760.1982
Abstract
A variety of substrates can be employed in enzyme immunoassays (EIAs) for the measurement of enzyme-labeled immunoreactants. We compared the sensitivities of a fluorescent and a colorigenic substrate in an EIA system for the measurement of Haemophilus influenza purified polyribose phosphate. After a 10-min substrate incubation, the EIA in which the fluorescent substrate was used could detect 10 pg of polyribose phosphate per ml, whereas the EIA in which the colorigenic substrate was used required the addition of 640 pg of polyribose phosphate per ml to generate a positive reading. However, the use of longer substrate incubation periods led to an increase in sensitivity of the colorigenic EIA. After an incubation period of 240 min, the sensitivity was equal to that of the EIA in which the fluorescent substrate was used. These results suggest that the ultimate limit of sensitivity of EIA systems is determined by the nature of the antigen-antibody reactions. However, the use of high-energy substrates in EIA systems can allow for the attainment of maximal sensitivity after short enzyme-substrate incubation periods.This publication has 15 references indexed in Scilit:
- Detection of attograms of antigen by a high-sensitivity enzyme-linked immunoabsorbent assay (HS-ELISA) using a fluorogenic substrateJournal of Immunological Methods, 1980
- Indirect enzyme-linked immunosorbent assay for the quantitation of the type-specific antigen of Haemophilus influenzae b: A preliminary reportThe Journal of Pediatrics, 1980
- More sensitive immunoassaysNature, 1980
- Enzyme-linked immunosorbent assay (ELISA): a practical tool for rapid diagnosis of viruses and other infectious agents.1980
- Ultrasensitive enzymatic radioimmunoassay: application to detection of cholera toxin and rotavirus.Proceedings of the National Academy of Sciences, 1979
- Detection of Candida antigen in sera of patients with candidiasis by an enzyme-linked immunosorbent assay-inhibition techniqueJournal of Clinical Microbiology, 1979
- The rapid determination of binding constants for antiviral antibodies by a radioimmunoassay. An analysis of the interaction between hybridoma proteins and influenza virusMolecular Immunology, 1979
- ENZYME-LINKED IMMUNOSORBENT ASSAY (ELISA) FOR DETECTION OF HUMAN REOVIRUS-LIKE AGENT OF INFANTILE GASTROENTERITISThe Lancet, 1977
- Light emission techniques for the microestimation of femtogram levels of peroxidaseAnalytical Biochemistry, 1977
- ENZYME-IMMUNOASSAY1976