A Combined Chemical and Electrochemical Approach Using Bis(trifluoroacetoxy)iodobenzene and Glucose Oxidase for the Detection of Chlorinated Phenols
- 1 November 1997
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (21) , 4324-4330
- https://doi.org/10.1021/ac970369f
Abstract
A novel electrocatalytic approach using a chemical reaction and an enzymatic reaction has been developed for the measurement of 18 chlorophenol congeners, including highly chlorinated pollutants such as pentachlorophenol, 2,3,5,6-tetrachlorophenol, 2,3,4,6-tetrachlorophenol, and several trichlorophenols. Chlorophenols were oxidized to chlorobenzoquinones with very high yields using bis(trifluoroacetoxy)iodobenzene in 0.1 M trichloroacetic acid, pH 1.5, at ambient temperature. UV-visible spectrophotometry, cyclic voltammetry, and HPLC have been used to characterize the reaction products and yields. Together with glucose oxidase immobilized on a working glassy carbon electrode (+0.45 V vs Ag/AgCl), chlorinated benzoquinones have been demonstrated to be efficient mediators in a glucose oxidase/glucose system. In this approach, glucose oxidase was readily reduced by excess glucose to provide a non-rate-limiting source of electron flow toward the electrode. The oxidation products of chlorophenols then recycled the reduced glucose oxidase to its active oxidative state, i.e., mediating the rate-limiting electron transfer from the enzyme to the electrode. At pH 3.5, linear behavior of the current response was observed up to 200 nM for all chlorophenol oxidation products. The detection limit of this method for both pentachlorophenol and 2,3,5,6-tetrachlorophenol was about 4 nM, which is close to the maximum allowable contamination level of pentachlorophenol in water samples (2.7 nM). The detection limit obtained for pentachlorophenol could also be considered superior to the result obtained with the PCP immunoassay technology (13.3 nM).Keywords
This publication has 17 references indexed in Scilit:
- Applicability of Capillary Electrophoresis with Amperometric Detection to Study Degradation of Chlorophenols in Contaminated SoilEnvironmental Science & Technology, 1997
- Peer Reviewed: Environmental Biosensors: A Status ReportEnvironmental Science & Technology, 1996
- An electrocatalytic approach for the measurement of chlorophenolsAnalytica Chimica Acta, 1996
- A nanosecond laser flash photolysis study of aqueous 4-chlorophenolJournal of Photochemistry and Photobiology A: Chemistry, 1996
- Identification of Halogenated Compounds in Chlorinated Seawater and Drinking Water Produced Offshore Using n-Pentane Extraction and Open-Loop Stripping TechniqueEnvironmental Science & Technology, 1994
- Characterization of reaction products from the enzyme catalyzed oxidation of phenolic pollutantsWater Research, 1994
- The Chloroperoxidase-Catalyzed Oxidation of Phenols. Mechanism, Selectivity, and Characterization of Enzyme-Substrate ComplexesBiochemistry, 1994
- Photomineralisation of 4-chlorophenol sensitised by titanium dioxide: a study of the intermediatesJournal of Photochemistry and Photobiology A: Chemistry, 1993
- Glucose oxidase: an ideal enzymeBiosensors and Bioelectronics, 1992
- Kel-F-graphite composite electrode as an electrochemical detector for liquid chromatography and application to phenolic compoundsAnalytical Chemistry, 1981