Brief communication: Measurement size, precision, and reliability in craniofacial anthropometry: Bigger is better
- 1 April 1993
- journal article
- research article
- Published by Wiley in American Journal of Physical Anthropology
- Vol. 90 (4) , 495-500
- https://doi.org/10.1002/ajpa.1330900409
Abstract
In this paper we examine the results of an intraobserver measurement error study involving 49 craniofacial variables that ranged in size from less than 1 cm to approximately 20 cm. Repeat measurements were taken on 10 male and 10 female adult subjects (19–59 years old). Our focus is on the relationship between measurement size and measurement error across the 49 variables. We found that the size of the variable showed no relationship with the magnitude of the error as measured by the technical error of measurement. When the error was expressed as a coefficient of relative variation (Malina et al.: Vital and Health Statistics, Series 11, No. 23. Washington, DC: US Department of Health and Human Services, 1973), this quantity was negatively associated with the size of the measurement. Conversely, reliability (Fleiss: The Design and Analysis of Experiments. New York: John Wiley & Sons, 1986) was positively correlated with measurement size. We did not find effects of scale (Marks et al.: Am. J. Epidemiol. 130:578–587, 1989) within the individual measurements. Thus, for the range of size of the craniofacial measurements in this study, measurement size must be added to the list of factors such as ease of locating landmarks, measurement technique, and systematic bias in the application of the technique that can affect precision and reliability in anthropometry.Keywords
This publication has 8 references indexed in Scilit:
- Sources of measurement variation in child anthropometry in the Malawi maternal and child nutrition studyAmerican Journal of Human Biology, 1991
- THE SECOND NATIONAL HEALTH AND NUTRITION EXAMINATION SURVEY 1976%1980American Journal of Epidemiology, 1989
- Reliability of anthropometric methods and replicate measurementsAmerican Journal of Physical Anthropology, 1989
- Anthropometric Field Methods: Criteria for SelectionPublished by Springer Nature ,1979
- The identification and evaluation of measurement variability in the anthropometry of preschool childrenAmerican Journal of Physical Anthropology, 1975
- A univariate and multivariate examination of measurement error in anthropometryAmerican Journal of Physical Anthropology, 1974
- The consistency of anthropometric measurementsAmerican Journal of Physical Anthropology, 1950
- Critical Examination of Physical Anthropometry on the LivingProceedings of the American Academy of Arts and Sciences, 1934