Enhancement of signal quality in esophageal recordings of diaphragm EMG
- 1 April 1997
- journal article
- clinical trial
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 82 (4) , 1370-1377
- https://doi.org/10.1152/jappl.1997.82.4.1370
Abstract
Sinderby, Christer A., Jennifer C. Beck, Lars H. Lindström, and Alejandro E. Grassino. Enhancement of signal quality in esophageal recordings of diaphragm EMG. J. Appl. Physiol. 82(4): 1370–1377, 1997.—The crural diaphragm electromyogram (EMGdi) is recorded from a sheet of muscle, the fiber direction of which is mostly perpendicular to an esophageal bipolar electrode. The region from which the action potentials are elicited, the electrically active region of the diaphragm (EARdi) and the center of this region (EARdi ctr) may vary during voluntary contractions in terms of their position with respect to an esophageal electrode. Depending on the bipolar electrode’s position with respect to the EARdi ctr, the EMGdi is filtered to different degrees. The objectives of the present study were to reduce these filtering effects on the EMGdi by developing an analysis algorithm referred to as the “double-subtraction technique.” The results showed that changes in the position of the EARdi ctr by ±5 mm with respect to the electrode pairs located 10 mm caudal and 10 mm cephalad provided a systematic variation in the EMG power spectrum center-frequency values by ±10%. The double-subtraction technique reduced the influence of movement of the EARdi ctr relative to the electrode array on EMG power spectrum center frequency and root mean square values, increased the signal-to-noise ratio by 2 dB, and increased the number of EMG samples that were accepted by the signal quality indexes by 50%.Keywords
This publication has 12 references indexed in Scilit:
- Influence of bipolar esophageal electrode positioning on measurements of human crural diaphragm electromyogramJournal of Applied Physiology, 1996
- Effects of muscle-to-electrode distance on the human diaphragm electromyogramJournal of Applied Physiology, 1995
- Comparison of Diaphragm EMG Centroid Frequencies: Esophageal versus Chest Surface LeadsAmerican Review of Respiratory Disease, 1993
- Automatic selection of uncontaminated electromyogram as applied to respiratory muscle fatigueJournal of Applied Physiology, 1984
- Force reserve of the diaphragm in patients with chronic obstructive pulmonary diseaseJournal of Applied Physiology, 1983
- Power spectral analysis of the diaphragm electromyogramJournal of Applied Physiology, 1983
- Evaluation of human diaphragm fatigueJournal of Applied Physiology, 1982
- Electromyogram pattern of diaphragmatic fatigueJournal of Applied Physiology, 1979
- Role of the diaphragm in breathing in conscious normal man: an electromyographic studyJournal of Applied Physiology, 1960
- Electromyography of the diaphragm in man and transdiaphragmatic pressureJournal of Applied Physiology, 1960