Gradual Reduction of Endotracheal Tube Diameter during Mechanical Ventilation via Different Humidification Devices
- 1 December 1996
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 85 (6) , 1341-1349.
- https://doi.org/10.1097/00000542-199612000-00015
Abstract
Background: Limited data suggest that increased resistance to flow within endotracheal tubes (ETT) may occur in patients whose lungs are mechanically ventilated for more than 48 h, especially when airway humidification is inadequate. This could lead to sudden ETT obstruction or induce excessive loading during spontaneous breathing. Methods: Twenty-three such patients were randomly assigned to three types of airway humidifier based on three different working principles: a Fisher Paykell hot water system (n = 7), a Pall BB2215 heat and moisture exchanger (HME) hydrophobic filter (n = 8), and a Dar Hygrobac 35254111 HME hygroscopic filter (n = 8). The decrease in internal pressure along the ETT and the flow rate were measured in each patient every 2 days. An "effective inner diameter" was derived from these measurements and allowed the inner ETT configuration to be monitored. Results: On the first day of intubation, the mean diameter was similar in the three groups, and was slightly smaller than the in vitro diameter (mean +/- SD: 7.6 +/- 0.6 mm for Fisher-Paykell, 7.7 +/- 0.4 for Pall, and 7.5 +/- 0.4 for Dar). The mean diameter tended to decrease from day to day. At the end of the study, the overall reduction in mean diameter was significantly greater with the hydrophobic HME (Pall) than with the two other systems (Pall: -6.5 +/- 4% vs. 2.5 +/- 2.5% for Dar and 1.5 +/- 3% for Fisher-Paykell; P < 0.01 with analysis of variance). The same was true of the mean reduction in effective inner ETT diameter expressed per day of ventilation (-1.6 +/- 1.5% per day for Pall vs. -0.5 +/- 0.4% for Dar and -0.2 +/- 0.4% for Fisher-Paykell; P < 0.01). In four patients, the ETT became obstructed and emergency repeated tracheal intubation was required. The Pall HME and the Fisher-Paykell system were being used in three and one patient, respectively. Before obstruction, the reduction in ETT diameter was significantly greater for these four patients than for the remaining 23 patients (7.8 +/- 1.4% vs. 3.1 +/- 4.1%; P < 0.01). Conclusions: During prolonged mechanical ventilation, significant alterations in inner ETT configuration occur frequently and are influenced by the type of humidification device used. In vivo monitoring of ETT mechanical properties might be clinically useful.Keywords
This publication has 19 references indexed in Scilit:
- Performance Evaluation of Three Vaporizing Humidifiers and Two Heat and Moisture Exchangers in Patients with Minute Ventilation <10 L/minChest, 1992
- Inspiratory Pressure Support Compensates for the Additional Work of Breathing Caused by the Endotracheal TubeAnesthesiology, 1991
- Complications of Acute Respiratory FailureAmerican Review of Respiratory Disease, 1988
- Pressure Support Compensation for Inspiratory Work due to Endotracheal Tubes and Demand Continuous Positive Airway PressureChest, 1988
- Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unitCritical Care Medicine, 1988
- A review of the mechanisms and methods of humidification of inspired gasesIntensive Care Medicine, 1988
- Work of breathing through different sized endotracheal tubesCritical Care Medicine, 1986
- A comparison of five heat and moisture exchangersAnaesthesia, 1986
- Complications and consequences of endotracheal intubation and tracheotomyThe American Journal of Medicine, 1981
- Complications of assisted ventilationThe American Journal of Medicine, 1974