On the use of EPID‐based implanted marker tracking for 4D radiotherapy
- 24 November 2004
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (12) , 3492-3499
- https://doi.org/10.1118/1.1812608
Abstract
Four-dimensional (4D) radiotherapy delivery to dynamically moving tumors requires a real-time signal of the tumor position as a function of time so that the radiation beam can continuously track the tumor during the respiration cycle. The aim of this study was to develop and evaluate an electronic portal imaging device (EPID)-based marker-tracking system that can be used for real-time tumor targeting, or 4D radiotherapy. Three gold cylinders, 3 mm in length and 1 mm in diameter, were implanted in a dynamic lung phantom. The phantom range of motion was 4 cm with a 3-s "breathing" period. EPID image acquisition parameters were modified, allowing image acquisition in 0.1 s. Images of the stationary and moving phantom were acquired. Software was developed to segment automatically the marker positions from the EPID images. Images acquired in 0.1 s displayed higher noise and a lower signal-noise ratio than those obtained using regular (> 1 s) acquisition settings. However, the markers were still clearly visible on the 0.1-s images. The motion of the phantom blurred the images of the markers and further reduced the signal-noise ratio, though they could still be successfully segmented from the images in 10-30 ms of computation time. The positions of gold markers placed in the lung phantom were detected successfully, even for phantom velocities substantially higher than those observed for typical lung tumors. This study shows that using EPID-based marker tracking for 4D radiotherapy is feasible, however, changes in linear accelerator technology and EPID-based image acquisition as well as patient studies are required before this method can be implemented clinically.Keywords
This publication has 36 references indexed in Scilit:
- Tracking moving organs in real timeSeminars in Radiation Oncology, 2004
- Reduction in Acute Morbidity Using Hypofractionated Intensity-Modulated Radiation Therapy Assisted with a Fluoroscopic Real-Time Tumor-Tracking System for Prostate CancerThe Cancer Journal, 2003
- The leaf sweep algorithm for an immobile and moving target as an optimal control problem in radiotherapy deliveryMathematical and Computer Modelling, 2003
- Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopyCancer, 2002
- Detection of lung tumor movement in real-time tumor-tracking radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patientsMedical Physics, 2001
- Robotic motion compensation for respiratory movement during radiosurgeryComputer Aided Surgery, 2000
- Real-time tumour-tracking radiotherapyThe Lancet, 1999
- What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?Radiotherapy and Oncology, 1998
- Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomographyInternational Journal of Radiation Oncology*Biology*Physics, 1990