Failure and Hydrodynamic Function Testing of Explanted Pericardial and Porcine Bioprosthetic Valves
- 1 June 1989
- journal article
- review article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 203 (2) , 65-70
- https://doi.org/10.1243/pime_proc_1989_203_012_01
Abstract
The long-term durability and function of cardiac bioprostheses can be affected by both calcification and mechanical failure of the tissue. The mechanisms of failure and hydrodynamic function of 66 explanted bioprostheses have been studied. The majority of porcine valves were heavily calcified with leaflet tears adjacent to the calcification at the commissures. These tears caused prolapsed leaflets and regurgitation of between 30 and 70 per cent. Only three porcine valves had tissue failure in the absence of calcification. The majority of pericardial valves failed due to leaflet tears at the edge of the frame in the absence of macroscopic calcification. These tears also produced prolapsed leaflets and large regurgitation in hydrodynamic tests. Three pericardial valves were heavily calcified and stenotic without leaflet tears. Leaflet dynamics in the pericardial valves were affected by host tissue ingrowth which produced increased pressure drops across the valves, an asymmetrical open position and leaflet flutter. In the absence of calcification and leaflet tears, there was little change in the function of explanted porcine valves.Keywords
This publication has 15 references indexed in Scilit:
- Primary tissue failure in pericardial heart valvesThe Journal of Thoracic and Cardiovascular Surgery, 1987
- Patterns of failure in Ionescu-Shiley bovine pericardial bioprosthetic valvesThe Journal of Thoracic and Cardiovascular Surgery, 1987
- An improved pericardial bioprosthetic heart valve Design and laboratory evaluationEuropean Journal of Cardio-Thoracic Surgery, 1987
- Performance of the lonescu-Shiley Pericardial Valve in the Aortic Position: 100 Months Clinical ExperienceThe Thoracic and Cardiovascular Surgeon, 1986
- Anatomic analysis of removed prosthetic heart valves: Causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 1983Human Pathology, 1985
- In vivo hemodynamic comparison of porcine and pericardial valvesThe Journal of Thoracic and Cardiovascular Surgery, 1985
- Isolated Mitral Valve Replacement with the Hancock Bioprosthesis: A 13-Year AppraisalThe Annals of Thoracic Surgery, 1984
- Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral positionThe Journal of Thoracic and Cardiovascular Surgery, 1984
- Role of mechanical stress in calcification of aortic bioprosthetic valvesThe Journal of Thoracic and Cardiovascular Surgery, 1983
- Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patientsThe American Journal of Cardiology, 1981