Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilities
Open Access
- 7 June 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (6) , 1077-1082
- https://doi.org/10.1002/mrm.10174
Abstract
The quality of spectra in 1H magnetic resonance spectroscopy (MRS) is strongly affected by temporal signal instabilities during the acquisition. One reason for these instabilities are hardware imperfections, e.g., drifts of the main magnetic field in superconducting magnets. This is of special concern in high-field systems where the specification of the field stability is close to the spectral linewidth. A second major potential source of artifacts, particularly in clinical MRS, is patient motion. Using standard acquisition schemes of phase-cycled averaging of the individual acquisitions, long-term effects (field drifts) as well as changes on a shorter time scale (motion) can severely reduce spectral quality. The new technique for volume-selective MRS presented here is based on the additional interleaved acquisition of a navigator signal during the recovery time of the metabolite acquisition. It corrects for temporal signal instabilities by means of a deconvolution of the metabolite and the navigator signal. This leads to phase-corrected individual metabolite scans and upon summation to a phase-coherent averaging scheme. The interleaved navigator acquisition does not require any user interaction or supervision, while sequence efficiency is maintained. Magn Reson Med 47:1077–1082, 2002.Keywords
This publication has 21 references indexed in Scilit:
- 3D coronary MR angiography in multiple breath‐holds using a respiratory feedback monitorMagnetic Resonance in Medicine, 1995
- Reduction of signal fluctuation in functional MRI using navigator echoesMagnetic Resonance in Medicine, 1994
- Adaptive motion compensation in MRI: Accuracy of motion measurementMagnetic Resonance in Medicine, 1991
- Reference deconvolution. Elimination of distortions arising from reference line truncationJournal of Magnetic Resonance (1969), 1991
- In vivo proton spectroscopy in presence of eddy currentsMagnetic Resonance in Medicine, 1990
- Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopyNMR in Biomedicine, 1989
- Compensation of instrumental imperfections by deconvolution using an internal reference signalJournal of Magnetic Resonance (1969), 1988
- Spatial Localization in NMR Spectroscopy in VivoAnnals of the New York Academy of Sciences, 1987
- The correction of transient B0 field shifts following the application of pulsed gradients by phase correction in the time domainJournal of Magnetic Resonance (1969), 1986