Optical sensors for clinical monitoring
- 1 March 1995
- journal article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 39 (s104) , 37-54
- https://doi.org/10.1111/j.1399-6576.1995.tb04254.x
Abstract
Technical progresses make it now possible to monitor well known or new parametersin vivoor in the laboratory with high accuracy. Especially optical sensors can advantageously be used for many medical applications. To understand advantage and limitation of a measuring technique the basic processes will be shortly discussed. There are two types of optical sensors: 1) optical sensors which use intrinsic indicators (as for example haemoglobin or cytochromes). In this chapter tissue photometry and evaluation methods for multicomponent scattering systems are discussed; nearinfrared and NADH fluorescence measurements are shortly mentioned. 2) Optical sensors using extrinsic indicators (optodes). As extrinsic indicators absorbant as well as luminescent indicators are used. Luminescence indicators are especially sensitive. Microoptodes and two dimensional imaging is possible. From the basic molecular reactions of the sensing mechanisms follows that for most of the indicator reactions there is a non‐linear, almost hyperbolic relationship between optical signal and concentration of the analyte. Consequently, accuracy as well as sensitivity of the optode is changing in a given measuring range. Therefore, the optical indicator must be carefully selected. Lifetime (or phase angle) measurements have the advantage that their accuracy is independent of indicator concentration, intensity of the light source and light transport between the sensing element and the photometric setup. Optodes can be manufactured as flexible membranes permeable for the analyte. This facilitates the construction of fibreoptic sensors. As practical examples oxygen optodes, ion optodes, opticalpCO2sensors, and bench‐top as well as intra‐arterial blood gas measurements are discussed in detail.Keywords
This publication has 78 references indexed in Scilit:
- Presentation and evaluation of a new optical sensor for respiratory rate monitoringJournal of Clinical Monitoring and Computing, 1994
- Continuous monitoring of blood gases during hypercapnia in a patient with severe acute lung failureIntensive Care Medicine, 1994
- Fluorescent Chemosensors for Monitoring Potassium in Blood and across Biological MembranesPublished by American Chemical Society (ACS) ,1993
- Clinical evaluation - continuous real-time intra-arterial blood gas monitoring during anesthesia and surgery by fiber optic sensorJournal of Clinical Monitoring and Computing, 1992
- Luminescence chemical sensors for biomedical applications: scope and limitationsAnalytica Chimica Acta, 1991
- Progress in the development of a fluorescent intravascular blood gas system in manJournal of Clinical Monitoring and Computing, 1990
- Fiber-optic sensor for carbon dioxide with a ph indicator dispersed in a poly(ethylene glycol) membraneAnalytica Chimica Acta, 1989
- Evaluation of the Gas-STAT® fluorescence sensors for continuous measurement of pH,pCO2andpO2during cardiopulmonary bypass and hypothermiaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- Untersuchungen über die Sauerstoffsättigung des menschlichen ArterienblutesNaunyn-Schmiedebergs Archiv für experimentelle Pathologie und Pharmakologie, 1935
- Fortlaufende Registrierung der Sauerstoffsättigung im Blute an Uneröffneten BlutgefässenJournal of Molecular Medicine, 1934