Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner
- 1 November 2006
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 79 (947) , 888-892
- https://doi.org/10.1259/bjr/66519303
Abstract
Recent rapid progress in CT technology has yielded equipment with large numbers of detector rows and standard computed tomography dose index (CTDI) is therefore no longer an adequate integration range. An integration range of 300 mm is necessary to accurately measure dose under a nominal beam width of 128 mm due to scattered radiation. However, such a long phantom is inconvenient to use routinely in cone-beam CT patient dose checking. To assess patient dose accurately with standard dosimetry methods, we determined a conversion factor (CF) which was calculated from the weighted dose profile integral (DPIw) for the 300 mm integration range with a 300 mm long CTDI phantom using a 300 mm long ionization chamber divided by that for the 100 mm integration range with a standard CTDI phantom (140 mm long) with a 100 mm long chamber. CF values increase with increasing nominal beam width and effective energy in the range from 1.5 to 2.0. CF values can also be adapted for use with other CT systems as their dose profiles are thought to be analogous to those for the 300 mm phantom and are useful in any hospital situation to assess accurate patient doses using standard dosimetry methods.Keywords
This publication has 10 references indexed in Scilit:
- Real-Time Volumetric Imaging of Human Heart Without Electrocardiographic Gating by 256-Detector Row Computed TomographyJournal of Computer Assisted Tomography, 2005
- Clinical Potentials for Dynamic Contrast-Enhanced Hepatic Volumetric Cine Imaging with the Prototype 256-MDCT ScannerAmerican Journal of Roentgenology, 2005
- Enlarged longitudinal dose profiles in cone‐beam CT and the need for modified dosimetryMedical Physics, 2005
- Clinical potentials of the prototype 256-detector row CT-scanner1Academic Radiology, 2005
- Volumetric Cine Imaging for Cardiovascular Circulation Using Prototype 256-Detector Row Computed Tomography Scanner (4-Dimensional Computed Tomography)Journal of Computer Assisted Tomography, 2005
- Novel methods of measuring single scan dose profiles and cumulative dose in CTMedical Physics, 2004
- Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imagingMedical Physics, 2004
- Development and performance evaluation of the first model of 4-D CT-scannerIEEE Transactions on Nuclear Science, 2003
- Large-area two-dimensional detector for real-time three-dimensional CT (4D CT)Published by SPIE-Intl Soc Optical Eng ,2001
- Estimated fetal radiation dose from multislice CT studies.American Journal of Roentgenology, 1990