Sensitivity‐encoded coronary MRA at 3T
Open Access
- 23 July 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (2) , 221-227
- https://doi.org/10.1002/mrm.20062
Abstract
Long scan times are still a main limitation in free-breathing navigator-gated 3D coronary MR angiography (MRA). Unlike other MRI applications, high-resolution coronary MRA has not been amenable to acceleration by parallel imaging techniques due to signal-to-noise ratio (SNR) concerns. In the present work, mitigating SNR limitations by the transition to higher static magnetic field strength is proposed, thus enabling scan time reduction by the parallel sensitivity encoding (SENSE) technique. The study reports the implementation and evaluation of free-breathing navigator-gated 3D coronary MRA with SENSE at 3T. Results from 11 healthy subjects indicate that the approach permits significant scan time reduction in MRA of the left and right coronary systems. Quantitative image analysis and visual grading suggest that two-fold scan acceleration can be accomplished at nearly preserved image quality. The additional experiments appear to demonstrate that parallel MRA equally permits enhancing volume coverage and spatial resolution while maintaining scan time. Magn Reson Med 52:221–227, 2004.Keywords
This publication has 27 references indexed in Scilit:
- “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiogramsMagnetic Resonance in Medicine, 2002
- Preliminary report on in vivo coronary MRA at 3 Tesla in humansMagnetic Resonance in Medicine, 2002
- Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3Dk-space reorderingMagnetic Resonance in Medicine, 2001
- Cardiac real-time imaging using SENSEMagnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Breathhold Three-Dimensional Coronary Magnetic Resonance Angiography Using Real-Time Navigator TechnologyJournal of Cardiovascular Magnetic Resonance, 1999
- 3D coronary MR angiography in multiple breath‐holds using a respiratory feedback monitorMagnetic Resonance in Medicine, 1995
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- Fast algorithms for low-level visionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1990