Should a VVIR Pacemaker Increase the Heart Rate with Standing?
- 1 March 1992
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 15 (3) , 288-294
- https://doi.org/10.1111/j.1540-8159.1992.tb06498.x
Abstract
To assess the usefulness of incorporating a posture sensor into a ventricular inhibited rate modulated pacemaker, the hemodynamic effects of increasing the ventricular pacing rate with standing were studied in 15 pacemaker dependent patients aged 55 +/- 3.5 years. In a randomized cross-over design, the pacing rate remained at 70 or was increased to 100 beats/min immediately prior to standing. Blood pressure was monitored continuously and forearm blood flow was measured by venous occlusion plethysmography. There was no difference in supine blood pressure (117 +/- 4/63 +/- 3 compared to 118 +/- 5/64 +/- 4 mmHg) or forearm blood flow (2.88 +/- 0.36 vs 2.94 +/- 0.32 mL/100 mL/min) before the 70 or 100 pacing rate intervention. With standing, blood pressure fell to an equivalent degree at the two pacing rates (fall in mean blood pressure at 70 beats/min 6 +/- 4 and at 100 beats/min 8 +/- 2 mmHg, P = 0.7). After 1 minute of standing differences in blood pressure were similar, but after 2.5 minutes of standing the increase in mean blood pressure was less at 70 than at 100 beats/min (increase from control 28 +/- 2 compared to 36 +/- 3 mmHg, P = 0.002). Forearm blood flow decreased after standing for 1 and 2.5 minutes but there was no difference between the 70 and 100 pacing rates (fall in forearm blood flow at 2.5 minutes 0.50 +/- 0.24 and 0.59 +/- 0.25 mL/100 mL/cm2).(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 24 references indexed in Scilit:
- The Plasma Catecholamine Responses to Ventricular Pacing: Implications for Rate Responsive PacingPacing and Clinical Electrophysiology, 1990
- Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principleActa Anaesthesiologica Scandinavica, 1990
- New insights into pacemaker syndrome gained from hemodynamic, humoral and vascular responses during ventriculo-atrial pacingThe American Journal of Cardiology, 1990
- Effects of Peripheral Vasoconstriction on the Blood Pressure in the Finger, Measured Continuously by a New Noninvasive Method (The Finapres®)Anesthesiology, 1985
- Evaluation of the Penàz servo-plethysmo-manometer for the continuous, non-invasive measurement of finger blood pressureBasic Research in Cardiology, 1984
- Programmed Atrial Pacing for Orthostatic HypotensionActa Medica Scandinavica, 1983
- Atrial Tachypacing for Primary Orthostatic HypotensionNew England Journal of Medicine, 1980
- Atrial Tachypacing in the Treatment of a Patient with Primary Orthostatic HypotensionNew England Journal of Medicine, 1980
- Three cases of hypotension and syncope with ventricular pacing: Possible role of atrial reflexesThe American Journal of Cardiology, 1978
- A note on the analysis of repeated measurements of the same subjectsJournal of Chronic Diseases, 1962