Intraoperative localization using an armless, frameless stereotactic wand
- 1 March 1993
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 78 (3) , 510-514
- https://doi.org/10.3171/jns.1993.78.3.0510
Abstract
A technique of "frameless" stereotaxy that allows real-time intraoperative neurosurgical localization is described. The system is composed of four components: a hand-held probe containing two ultrasonic emitters, a microphone array that is rigidly affixed to the operating table in proximity to the surgical field, hardware to control and detect timing of signal production and reception, and a color graphics computer workstation with software to calculate and present the location of the probe tip on reconstructed neuroimaging studies. Unlike previously reported mechanical or sonic navigational devices, this system is adaptable to a wide array of neurosurgical instruments, allows free movement of the operating table and conventional patient draping, and has accuracy in the hostile operating room environment that rivals that of frame stereotaxy. In the operating room environment, using four pulse pairs with the wand positioned optimally, reproducibility of a point in space is +/- 0.6 mm. The wand has a broad range of orientations that maintain error at or below 1.0 mm. The mean error when measuring distances within a 1000-cu cm cube is 1.1 +/- 1.0 mm (1.0% +/- 0.7%). The ability to localize a fourth point (a target) in space is typically within 1.5 mm (using computerized tomography scans with a 1-mm slice thickness) but is dependent on several variables. This technology provides a powerful yet flexible tool in the neurosurgical operating room.Keywords
This publication has 8 references indexed in Scilit:
- Stereotactic Craniotomy: Methods and Results Using the Brown-Roberts-Wells Stereotactic FrameNeurosurgery, 1989
- A frameless stereotaxic operating microscope for neurosurgeryIEEE Transactions on Biomedical Engineering, 1989
- Volumetric Stereotactic Surgical Resection of Intra-axial Brain Mass LesionsMayo Clinic Proceedings, 1988
- A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgeryIEEE Transactions on Biomedical Engineering, 1988
- Results of Computed Tomography-based Computer-assisted Stereotactic Resection of Metastatic Intracranial TumorsNeurosurgery, 1988
- Three-dimensional digitizer (neuronavigator): New equipment for computed tomography-guided stereotaxic surgerySurgical Neurology, 1987
- A frameless stereotaxic integration of computerized tomographic imaging and the operating microscopeJournal of Neurosurgery, 1986