Abstract
We have developed a prototype apparatus for real-time closed-loop measurement and correction of aberrations in the human eye. The apparatus uses infrared light to measure the wave-front aberration at 25 Hz with a Hartmann–Shack sensor. Defocus is removed by a motorized optometer, and higher-order aberrations are corrected by a membrane deformable mirror. The device was first tested with an artificial eye. Correction of static aberrations takes approximately five iterations, making the system capable of following aberration changes at 5 Hz. This capability allows one to track most of the aberration dynamics in the eye. Results in living eyes showed effective closed-loop correction of aberrations, with a residual uncorrected wave front of for a 4.3-mm pupil diameter. Retinal images of a point source in different subjects with and without adaptive correction of aberrations were estimated in real time. The results demonstrate real-time closed-loop correction of aberration in the living eye. An application of this device is as electro-optic “spectacles” to improve vision.
Keywords
This publication has 12 references indexed in Scilit:
- A low cost adaptive optics system using a membrane mirrorOptics Express, 2000
- Laboratory and field demonstration of a low cost membrane mirror adaptive optics systemOptics Communications, 2000
- Phase plates for wave-aberration compensation in the human eye.Optics Letters, 2000
- Adaptive control of a micromachined continuous-membrane deformable mirror for aberration compensationApplied Optics, 1999
- Correction of the aberrations in the human eye with a liquid-crystal spatial light modulator: limits to performanceJournal of the Optical Society of America A, 1998
- Supernormal vision and high-resolution retinal imaging through adaptive opticsJournal of the Optical Society of America A, 1997
- Flexible mirror micromachined in siliconApplied Optics, 1995
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994
- High-resolution imaging of the living human fovea: measurement of the intercenter cone distance by speckle interferometryOptics Letters, 1989
- Active optical depth resolution improvement of the laser tomographic scannerApplied Optics, 1989