Experimentelle Untersuchungen zur Stark-Verbreiterung der Balmer-Linien Hα und Hβ / Experimental Investigation of the Stark Broadening of the Balmer Lines Hα and Hβ
Open Access
- 1 November 1973
- journal article
- Published by Walter de Gruyter GmbH in Zeitschrift für Naturforschung A
- Vol. 28 (11) , 1794-1800
- https://doi.org/10.1515/zna-1973-1106
Abstract
The profiles of the Stark broadened Balmer lines Hα and Hβ have been measured in a wide range of temperature and electron density. By the use of different light sources (3 wallstabilized arcs of different design, a pulsed discharge tube and a plexiglass-capillary discharge) the range was ex- tended to 1.0·104≦T≦3.2·104 °K for the plasma temperature and to 1·1016≦ne≦55·1016 cm−3 for the electron density in the Hβ-scale. The experimental profiles of the Hα-line agree with generalized impact approximations if the condition: ne 2/3/T>2·107 cm−2 grad−1 is fulfilled. Disagreements between the Hα and Hβ electron density scale can be removed applying an empirical correction-factor to the electron density obtained from the half-width of Hα.Keywords