Programmable Selectivity for GC with Series-Coupled Columns Using Pulsed Heating of the Second Column
- 12 April 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (10) , 2215-2223
- https://doi.org/10.1021/ac020614h
Abstract
A series-coupled ensemble of a nonpolar dimethyl polysiloxane column and a polar trifluoropropylmethyl polysiloxane column with independent at-column heating is used to obtain pulsed heating of the second column. For mixture component bands that are separated by the first column but coelute from the column ensemble, a temperature pulse is initiated after the first of the two components has crossed the column junction point and is in the second column, while the other component is still in the first column. This accelerates the band for the first component. If the second column cools sufficiently prior to the second component band crossing the junction, the second band experiences less acceleration, and increased separation is observed for the corresponding peaks in the ensemble chromatogram. High-speed at-column heating is obtained by wrapping the fused-silica capillary column with resistance heater wire and sensor wire. Rapid heating for a temperature pulse is obtained with a short-duration linear heating ramp of 1000 °C/min. During a pulse, the second-column temperature increases by 20−100 °C in a few seconds. Using a cold gas environment, cooling to a quiescent temperature of 30 °C can be obtained in ∼25 s. The effects of temperature pulse initiation time and amplitude on ensemble peak separation and resolution are described. A series of appropriately timed temperature pulses is used to separate three coeluting pairs of components in a 13-component mixture.Keywords
This publication has 14 references indexed in Scilit:
- Portable Gas Chromatograph with Tunable Retention and Sensor Array Detection for Determination of Complex Vapor MixturesAnalytical Chemistry, 2003
- Selectivity Enhancement for High-Speed GC Analysis of Volatile Organic Compounds with Portable Instruments Designed for Vacuum-Outlet and Atmospheric-Pressure Inlet Operation Using Air as the Carrier GasAnalytical Chemistry, 2001
- High-Speed GC and GC/Time-of-Flight MS of Lemon and Lime Oil SamplesAnalytical Chemistry, 2001
- High-Speed GC and GC/MS with a Series-Coupled Column Ensemble Using Stop-Flow OperationAnalytical Chemistry, 2001
- Fast GC instrumentation and analysis for field applicationsField Analytical Chemistry & Technology, 2001
- Development and evaluation of a low thermal mass gas chromatograph for rapid forensic GC-MS analysesField Analytical Chemistry & Technology, 2001
- Pressure-Tunable Column Selectivity for High-Speed Vacuum-Outlet GCAnalytical Chemistry, 2000
- Fast Temperature Programming on Fused-Silica Open-Tubular Capillary Columns by Direct Resistive HeatingJournal of Chromatographic Science, 1995
- Compact gas chromatograph probe for gas chromatography/mass spectrometry utilizing resistively heated aluminum-clad capillary columnsAnalytical Chemistry, 1989
- Programmed Temperature Gas ChromatographyAnalytical Chemistry, 1958