Electrochemically Mediated Electrodeposition/Electropolymerization To Yield a Glucose Microbiosensor with Improved Characteristics
- 1 January 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (2) , 368-372
- https://doi.org/10.1021/ac015628m
Abstract
A procedure is described that provides for electrochemically mediated deposition of enzyme and a polymer layer permselective for endogenous electroactive species. Electrodeposition was first employed for the direct immobilization of glucose oxidase to produce a uniform, thin, and compact film on a Pt electrode. Electropolymerization of phenol was then employed to form an anti-interference and protective polyphenol film within the enzyme layer. In addition, a stability-reinforcing membrane derived from (3-aminopropyl)trimethoxysilane was constructed by electrochemically assisted cross-linking. This hybrid film outside the enzyme layer contributed to the improved stability and permselectivity. The resulting glucose sensor was characterized by a short response time (2), low interference from endogenous electroactive species, and working lifetime of more than 50 days.Keywords
This publication has 25 references indexed in Scilit:
- Disposable interference-free glucose biosensor based on an electropolymerised poly(pyrrole) permselective filmAnalytica Chimica Acta, 2000
- Electropolymerization of hydroxybenzene and aminobenzene isomers on platinum electrodes to assemble interference-free electrochemical biosensorsElectrochimica Acta, 1996
- Amperometric biosensors produced by immobilization of redox enzymes at polythiophene‐modified electrode surfacesAdvanced Materials, 1996
- The modification of enzyme electrode properties with non-conducting electropolymerised filmsBiosensors and Bioelectronics, 1995
- Organic Phase Enzyme Electrode Operated in Water-Free SolventsAnalytical Chemistry, 1994
- Reproducible Electrodeposition Technique for Immobilizing Glucose OxidasePublished by American Chemical Society (ACS) ,1994
- Electrodeposition of glucose oxidase for the fabrication of miniature sensorsSensors and Actuators B: Chemical, 1993
- Modification of electrode surfaces with oxidised phenols to confer selectivity to amperometric biosensors for glucose determinationAnalytica Chimica Acta, 1993
- Electropolymerized films to prevent interferences and electrode fouling in biosensorsBiosensors and Bioelectronics, 1991
- Polaromicrotribometric study of polyphenylene oxide film formation on metal electrodes by electrolysis of disubstituted phenolsElectrochimica Acta, 1977