Local INR correction: justification for a simplified approach.
- 1 September 1997
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 50 (9) , 783-789
- https://doi.org/10.1136/jcp.50.9.783
Abstract
AIMS: Errors in reporting International Normalised Ratios (INR) may be corrected by assignment of a System International Sensitivity Index (System ISI). This 57 centre study tests the validity of several procedures for INR correction. METHODS: Prothrombin times of eight lyophilised coumarin calibrants, a lyophilised normal pool calibrant, and eight frozen coumarin plasmas were determined at each centre. The calibrants were calibrated using international reference preparations. The eight frozen coumarin plasmas were calibrated in a four centre international exercise. The relations tested were: (a) the logarithm of local prothrombin time against the logarithm of reference prothrombin time; (b) reference INR against local prothrombin time; and (c) logarithm of reference INR against logarithm of local prothrombin time. These methods were analysed by both linear and orthogonal regression. RESULTS: All system groups required correction, the mean percentage deviation of the uncorrected data from the calibrated values was 19.0%. There was also considerable variation in INR, with the coefficient of variance (CV) ranging from 11.30 to 17.29%. Correction of INR was possible with all methods (CV reduced to < 7%). However, only when a plot of the logarithm of local prothrombin time against the logarithm of reference prothrombin time was fitted by orthogonal regression, or a plot of logarithm of reference INR against logarithm of local prothrombin time was fitted by either type of regression analysis, did the best fit line through the calibrant plasmas also pass close to the local mean normal prothrombin time. CONCLUSIONS: While INR correction may be achieved by all the above methods, that relating log reference INR to log local prothrombin time by linear regression analysis is the simplest to perform.Keywords
This publication has 9 references indexed in Scilit:
- System ISI calibration: a universally applicable scheme is possible only when coumarin plasma calibrants are usedBritish Journal of Haematology, 1997
- A partial factor V deficiency in anticoagulated lyophilized plasmas has been identified as a cause of the international normalized ratio discrepancy in the external quality assessment schemeThrombosis Research, 1995
- The effect of freezing and freeze drying coumarinized plasma on international normalized ratiosBlood Coagulation & Fibrinolysis, 1995
- Multi-Center Study of Replacement of the International Reference Preparation for Thromboplastin, Rabbit, PlainThrombosis and Haemostasis, 1993
- Assessment of value of calibrated lyophilised plasmas to determine International Sensitivity Index for coagulometers.Journal of Clinical Pathology, 1992
- Comparison of Two Automated Coagulometers and the Manual Tilt-Tube Method for the Determination of Prothrombin TimeAmerican Journal of Clinical Pathology, 1989
- The Effect of Some Instruments for Prothrombin Time Testing on the International Sensitivity Index (ISI) of Two Rabbit Tissue Thromboplastin ReagentsThrombosis and Haemostasis, 1989