Transesophageal Echocardiographic Guidance of Transseptal Left Heart Catheterization During Radiofrequency Ablation of Left‐Sided Accessory Pathways in Humans
- 1 March 1996
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 19 (3) , 272-281
- https://doi.org/10.1111/j.1540-8159.1996.tb03327.x
Abstract
Radiofrequency ablation (RFA) of left-sided accessory pathways can be achieved using catheters introduced by a retrograde or transseptal approach. Transesophageal echocardiography (TEE) has previously been demonstrated to be safe and efficacious in guiding transseptal puncture in patients during mitral valvuloplasty (MV). This study was undertaken to assess the feasibility, safety, and clinical utility of TEE during transsepta! puncture and RFA of left-sided accessory pathways. Methods: TEE was performed during transseptal puncture in 30 patients (41 ± 12 years, 19 females), 15 patients during attempted RFA of a left-sided accessory pathway and 15 patients during attempted balloon MV. Results: There was no difference in age, sex distribution, or procedural complications when MV patients were compared to RFA patients. At baseline, left atrial dimension was increased and congestive heart failure was more common when MV patients were compared to RFA patients (P < 0.05) Adequate baseline two-dimensional and Doppler TEE images were obtained in all patients. One patient sustained mild esophageal bleeding during the TEE, Positioning of the transseptal catheter in the fossa ovalis was facilitated and confirmed by TEE in 29 of 30 cases. One case of cardiac perforation occurred and was associated with inadequate TEE localization of the fossa ovalis. Thrombus was detected on the transseptal catheter by TEE in two cases prior to systemic heparinization. In both cases, thrombus was removed without embolic event. Conclusions: TEE safely guides transseptal puncture in patients undergoing RFA of left-sided accessory pathways. TEE markers of the fossa ovalis facilitate puncture and may reduce the risk of cardiac perforation particularly in patients with a normal size left atrium. TEE may be especially valuable for identifying thrombus during transseptal puncture.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of the retrograde and transseptal methods for ablation of left free wall accessory pathwaysJournal of the American College of Cardiology, 1993
- Mitral balloon valvuloplasty with transesophageal echocardiography without using fluoroscopyCatheterization and Cardiovascular Diagnosis, 1992
- Doppler detection of valvular regurgitation after radiofrequency ablation of accessory connectionsThe American Journal of Cardiology, 1992
- Usefulness of adenosine in augmenting ventricular preexcitation for noninvasive localization of accessory pathwaysThe American Journal of Cardiology, 1992
- Aortic Leaflet Perforation During Radiofrequency AblationPacing and Clinical Electrophysiology, 1991
- Catheter ablation using radiofrequency current to cure symptomatic patients with tachyarrhythmias related to an accessory atrioventricular pathway.Circulation, 1991
- Echocardiographic Contrast Enhancement of Poor or Weak Continuous-Wave Doppler SignalsEchocardiography, 1987
- Complications of transseptal left heart catheterizationThe American Journal of Cardiology, 1965
- A new technic for left ventricular angiocardiography and transseptal left heart catheterizationThe American Journal of Cardiology, 1960
- Transeptal Left Heart CatheterizationAnnals of Surgery, 1959