Pacing the Human Cardiac Conduction System During Open-heart Surgery
- 1 September 1974
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 50 (3) , 499-506
- https://doi.org/10.1161/01.cir.50.3.499
Abstract
Specialized fiber electrograms were recorded from selected sites along the His bundle and bundle branches during open-heart surgery in 26 patients. The heart was then paced from the same recording sites. Stimuli applied to the proximal His bundle recording site always resulted in His bundle pacing, which was characterized by a stimulus artifact-to-QRS interval which equaled or very nearly equaled the previously recorded His bundle electrogram-to-QRS interval, and no change in QRS duration or waveform from that recorded with a conducted atrial beat. When stimuli were applied to distal His bundle recording sites, the response was variable: in some instances, ventricular pacing occurred; in other instances, His bundle pacing occurred; and in still other instances, ventricular pacing occurred when high stimulus amplitudes were applied, while His bundle pacing occurred when the stimulus amplitudes were reduced below a range of 0.5-3.5 ma. Stimuli applied to the right or left bundle branch recording sites always resulted in ventricular pacing. Therefore, when stimuli are applied to specialized fiber recording sites and His bundle pacing results, it is certain that the site of origin of the previously recorded specialized fiber electrogram is the His bundle, but when ventricular pacing results, the site of origin of the previously recorded specialized fiber electrogram could be the distal His bundle or the bundle branches.Keywords
This publication has 8 references indexed in Scilit:
- His bundle recordings in right bundle-branch block coexisting with iatrogenic right ventricular pre-excitationHeart, 1972
- His bundle electrograms.Heart, 1971
- Retrograde activation of the his bundle in the human heartThe American Journal of Cardiology, 1971
- Specialized Cardiac Conduction SystemArchives of Surgery, 1970
- Unusual QRS complexes produced by pacemaker stimuli: With special reference to myocardial tunneling and coronary sinus stimulationAmerican Heart Journal, 1969
- A catheterization technique for His bundle stimulation and recording in the intact dogJournal of Applied Physiology, 1968
- Re-evaluation of the atrial contribution to ventricular functionThe American Journal of Cardiology, 1968
- A technique for ventricular pacing from the His bundle of the intact heartJournal of Applied Physiology, 1967