Determinants of intracardiac current in defibrillation. Experimental studies in dogs.
- 1 October 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 64 (4) , 818-823
- https://doi.org/10.1161/01.cir.64.4.818
Abstract
Defibrillation success depends upon the amount and distribution of intracardiac current (IC), because only a portion of total current flow between the paddles actually traverses the heart. Two determinants of IC, paddle size and shock energy, were evaluated. Studies were performed in 11 anesthetized dogs using a damped-sine wave form defibrillator. Intramyocardial electrode pairs were implanted subepicardially to subendocardially across the left and right ventricular free walls and in the interventricular septum. IC was quantitated by oscilloscopic measurements of the electric potential gradient (V/m) developed across the implanted electrodes during synchronized shocks of constant energy. External defibrillating paddle electrodes (paddles) were applied to the left and right lateral chest walls. An initial group of 6 dogs was given shocks with 8.5- or 13-cm-diameter paddles to assess the effect of standard vs. large paddles on IC. Mean IC values were substantially greater using 13-cm paddles (P < 0.01, paired t test). A 2nd group of 5 dogs was studied to determine more precisely the paddle size that produced the highest IC. A series of constant energy shocks using paddles of various sizes (8.5, 10, 12, 14, 16 cm in diameter) were given. In each dog, as paddle diameter increased from 8.5 to 16 cm, the IC increased, reached a maximum and then decreased. The maximum IC occurred at an average paddle size of 12 cm. To assess the effect of shock energy level on IC, shocks of variable energy using 8.5-cm-diameter paddles were given. Each 4-fold increase in delivered energy resulted in a doubling of IC. Defibrillating paddle diameter and delivered energy apparently are important determinants of IC flow.This publication has 10 references indexed in Scilit:
- Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure.Circulation, 1981
- The Energy for Ventricular Defibrillation — Too Little or Too Much?New England Journal of Medicine, 1978
- Transthoracic ventricular defibrillation in adults.BMJ, 1977
- The thoracic windows for electrical ventricular defibrillation currentAmerican Heart Journal, 1977
- Effectiveness of direct current defibrillation: role of paddle electrode size: IIAmerican Heart Journal, 1977
- Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardiumThe American Journal of Cardiology, 1975
- Energy Dosage for Human Trans-Chest Electrical Ventricular DefibrillationNew England Journal of Medicine, 1974
- Electrical Dose for Ventricular Defibrillation of Large and Small Animals Using Precordial ElectrodesJournal of Clinical Investigation, 1974
- Current distribution from defibrillation electrodes in a homogeneous torso modelJournal of Electrocardiology, 1969
- Termination of Ventricular Fibrillation in Man by Externally Applied Electric CountershockNew England Journal of Medicine, 1956