Influence of balloon size on initial success, acute complications, and restenosis after percutaneous transluminal coronary angioplasty. A prospective randomized study.
- 1 September 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 78 (3) , 557-565
- https://doi.org/10.1161/01.cir.78.3.557
Abstract
Restenosis after percutaneous transluminal coronary angioplasty (PTCA) is strongly associated with incomplete initial dilatation. To determine if oversized PTCA balloons would reduce the restenosis rate without increasing the risk of arterial dissection and acute complications, we prospectively randomized 336 patients to receive either smaller or larger balloons. Thirty-four percent of patients had multivessel disease and 18% had multisite dilatation. One hundred sixty-nine patients were randomized to PTCA with a larger balloon and 167 to PTCA with a smaller balloon. Balloon:artery diameter ratios were 1.13 +/- 0.14 in the larger group and 0.93 +/- 0.12 in the smaller group (p less than 0.001). The trial was halted as clinically important differences in acute complications emerged. Emergency bypass graft surgery, usually for the treatment of arterial dissection, was required in 7.1% of patients in the larger balloon group and 3.6% of patients in the smaller balloon group (p = 0.15). Myocardial infarction ...This publication has 18 references indexed in Scilit:
- Restenosis after successful percutaneous transluminal coronary angioplasty: The montreal heart institute experienceThe American Journal of Cardiology, 1987
- Influence of the methodology of percutaneous transluminal coronary angioplasty on restenosisThe American Journal of Cardiology, 1987
- Anticoagulation and restenosis after percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1987
- Restenosis after arterial angioplasty: A hemorrheologic response to injuryThe American Journal of Cardiology, 1987
- Restenosis after percutaneous transluminal coronary angioplasty: The emory university hospital experienceThe American Journal of Cardiology, 1987
- Mechanism of angioplasty and its relation to restenosisThe American Journal of Cardiology, 1987
- Reductions in Arterial Diameter Produced by Chronic Decreases in Blood Flow Are Endothelium-DependentScience, 1986
- Influence of Balloon Size on Recurrence Rate of Coronary Artery Stenosis. Results of a Prospective InvestigationPublished by Springer Nature ,1986
- Clinical and angiographic assessment 6 months after double vessel percutaneous coronary angioplastyJournal of the American College of Cardiology, 1985
- Higher balloon dilatation pressure in coronary angioplastyAmerican Heart Journal, 1984