Flow-through Chemiluminescence Sensor Using Immobilized Oxidases for the Selective Determination of l-Glutamate in a Flow-Injection System
- 23 August 2001
- journal article
- review article
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (8) , 929-933
- https://doi.org/10.2116/analsci.17.929
Abstract
A selective and sensitive chemiluminometric flow sensor for the determination of L-glutamate in serum, based on immobilized oxidases such as glutamate oxidase (GOD), uricase (UC) and peroxidase (POD), is described herein. The principle for the selective chemiluminometric detection for L-glutamate is based on coupled reactions of four sequentially aligned immobilized oxidases, UC/POD/GOD/POD in a flow cell. The immobilized UC was employed to decompose urate, which is one of the major interfering components in serum for a luminol-H2O2 chemiluminescence reaction. The H2O2 produced from the UC reaction readily reacted with reducing components, such as ascorbate and glutathione, and then the excess H2O2 was decomposed by the immobilized POD. L-Glutamate in the sample plug was enzymatically converted to H2O2 with immobilized GOD. Subsequently, the peroxide reacts with luminol on the immobilized POD to produce chemiluminescence, proportional to glutamate concentration. The enzymes were immobilized on tresylated poly(vinyl alcohol beads). The immobilized enzymes were packed into TPFE tube (1.0 mm i.d. x 60 cm), in turn, and used as a flow cell. The sampling rate was 30 h-1. The calibration graph for L-glutamate is linear for 20 nM-5 microM; the detection limit (signal-to-noise = 3) is 10 nM.Keywords
This publication has 19 references indexed in Scilit:
- Chemiluminometric branched chain amino acids determination with immobilized enzymes by flow-injection analysisAnalytica Chimica Acta, 1998
- Highly sensitive detection of l-glutamate by on-line amperometric micro-flow analysis based on enzymatic substrate recyclingTalanta, 1998
- Highly sensitive flow-injection determination of glucose in plasma using an immobilized pyranose oxidase and a chemiluminometric peroxidase sensorAnalytica Chimica Acta, 1997
- Concentration of Extracellular l-Glutamate Released from Cultured Nerve Cells Measured with a Small-Volume Online SensorAnalytical Chemistry, 1996
- On‐line amperometric assay of glucose, L‐glutamate, and acetylcholine using microdialysis probes and immobilized enzyme reactorsElectroanalysis, 1995
- Sequential enzymatic monitoring of glucose, ethanol and glutamate in bioreactor fermentation broth containing a high salt concentration by a multi-channel flow-injection analysis methodAnalytica Chimica Acta, 1995
- Chemiluminometric enzyme sensors for flow-injection analysisAnalytica Chimica Acta, 1995
- Determination of l-glutamate and l-glutamine by flow-injection analysis and chemiluminescence detection: comparison of an enzyme column and enzyme membrate sensorAnalytica Chimica Acta, 1993
- A chemiluminometric method for the determination of urea in serum using a three-enzyme bioreactorJournal of Bioluminescence and Chemiluminescence, 1988
- Purification and properties of a new enzyme, L-glutamate oxidase, from Streptomyces sp. X-119-6 grown on wheat bran.Agricultural and Biological Chemistry, 1983