Segmental Wall Motion Abnormalities During Telerobotic Totally Endoscopic Coronary Artery Bypass Grafting
- 1 April 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 94 (4) , 774-780
- https://doi.org/10.1097/00000539-200204000-00002
Abstract
In addition to single-lung ventilation (SLV), intrathoracic CO2 insufflation is mandatory for adequate exposure during totally endoscopic coronary artery bypass grafting. With transesophageal echocardiography, we investigated biventricular myocardial wall motion in 25 patients with isolated disease of the left anterior descending coronary artery who underwent totally endoscopic coronary artery bypass grafting with the “Da Vinci” robotic surgical system. At distinct time points during the operation, a cine loop of both ventricles was registered from a transgastric mid-short-axis view. Myocardial wall motion analysis was performed according to an established segmentation model of the left ventricle and to an established five-point scale for wall motion (1, normal; 5, dyskinesia). Significant alterations from preoperative baseline wall motion were visible in the septal, inferior, and anterior segments of the left ventricle at some time during the prebypass period, combined with a markedly decreased Pao2 under SLV and increased intrathoracic pressure. The same findings applied to the right ventricle; however, wall motion abnormalities were more pronounced here. After myocardial revascularization, weaning from cardiopulmonary bypass, CO2 deflation, and return to double-lung ventilation, myocardial wall motion recovered to baseline values. Clinically significant hemodynamic instability did not occur. The data suggest that robot-assisted coronary artery bypass grafting leads to significant prebypass alterations of biventricular segmental wall motion. On the basis of our data, it cannot be definitively stated whether the observed results were due to reduced oxygenation during SLV and thus “real” myocardial ischemia, intrathoracic CO2 insufflation with positive pressure leading to mechanical compromise of the heart, absolute or relative hypovolemia, or a combination of these factors. However, in this cohort, which consisted of patients with single-vessel disease and good ventricular function, these changes were of limited clinical relevance.Keywords
This publication has 22 references indexed in Scilit:
- Acute Hypovolemia May Cause Segmental Wall Motion Abnormalities in the Absence of Myocardial IschemiaAnesthesia & Analgesia, 1997
- Detection of Intraoperative Segmental Wall Motion Abnormalities by Transesophageal EchocardiographyAnesthesia & Analgesia, 1997
- Detection of myocardial ischemia by transesophageal echocardiographically determined changes in left ventricular area in patients undergoing coronary artery bypass surgeryJournal of Clinical Anesthesia, 1997
- Prolonged wall motion abnormalities after chest pain at rest in patients with unstable angina: A possible manifestation of myocardial stunningAmerican Heart Journal, 1994
- Altered Load Dependence of Postischemic MyocardiumAnesthesiology, 1991
- Acute Ventricular Wall Motion HeterogeneityAnesthesiology, 1991
- Relationship of Regional Wall Motion Abnormalities to Hemodynamic Indices of Myocardial Oxygen Supply and Demand in Patients Undergoing CABG SurgeryAnesthesiology, 1990
- The “Natural History” of Segmental Wall Motion Abnormalities in Patients Undergoing Noncardiac SurgeryAnesthesiology, 1990
- Left ventricular ejection fraction during cardiac surgery: a two-dimensional echocardiographic study.Circulation, 1983
- Comparison of Left Ventricular Ejection Fraction Assessed by Radionuclide Angiocardiography, Echocardiography and Contrast AngiocardiographyActa Medica Scandinavica, 1982