Reproducibility of incremental maximal cycle ergometer testing in patients with restrictive lung disease.
- 1 September 1993
- Vol. 48 (9) , 894-898
- https://doi.org/10.1136/thx.48.9.894
Abstract
BACKGROUND--Exercise testing has become an important tool in the diagnosis and treatment of restrictive lung disease. The reproducibility of variables measured during exercise testing was examined in subjects with stable restrictive lung disease. METHODS--Six subjects, who had never previously undergone exercise testing, each underwent three maximal incremental exercise studies on a bicycle ergometer conducted during a 28 day period. RESULTS--Data collected at rest, before exercise, were not significantly different during the three study days. Comparison of results at the end of the exercise tests from the three studies also revealed no evidence of a significant learning effect. Reproducibility of exercise performance by subjects was assessed by the coefficient of variation. The mean within subject coefficient of variation at the end of the exercise tests was 5.6% for work rate, 7.9% for exercise duration, and 9.5% for dyspnoea. The mean within subject coefficient of variation obtained at the end of the exercise tests was 5.3% for oxygen uptake (VO2), 2.5% for oxygen saturation (SaO2), 4.0% for heart rate (HR), 5.5% for minute ventilation (VE), 5.8% for respiratory frequency (f), and 4.6% for tidal volume (VT). The mean within subject coefficient of variation at 40% and 70% of maximal work rates for VO2 was 5.7% and 5.6% respectively, for SaO2 1.3% and 1.5%, for HR 4.8% and 4.0%, for VE 6.3% and 6.6%, for f 10.1% and 7.8%, and for VT 6.0% and 4.5%. CONCLUSIONS--Variables measured during clinical exercise testing in subjects with restrictive lung disease are highly reproducible. No significant learning effect was found on repeated testing in subjects who had never previously undergone exercise testing.Keywords
This publication has 27 references indexed in Scilit:
- Variability of Breathlessness Measurement in Patients with Chronic Obstructive Pulmonary Disease*Chest, 1991
- Diagnostic Value of Maximal Exercise Tidal VolumeChest, 1990
- Long-term Reproducibility of Respiratory Gas Exchange Measurements during Exercise in Patients with Stable Cardiac FailureChest, 1990
- Reproducibility of incremental maximal cycle ergometer tests in patients with mild to moderate obstructive lung diseasesLung, 1989
- Standardization of Spirometry—1987 UpdateAmerican Review of Respiratory Disease, 1987
- The Reproducibility of the Respiratory Responses to Maximum ExerciseRespiration, 1986
- Performance, ventilation, and oxygen consumption in three different types of exercise test in patients with chronic obstructive lung disease.Thorax, 1985
- Lung Function in Interstitial Lung DiseaseSeminars in Respiratory and Critical Care Medicine, 1984
- Pattern of breathing during exercise in patients with interstitial lung disease.Thorax, 1983
- An analysis of submaximal exercise responses in patients with sarcoidosis and fibrosing alveolitisRespiratory Medicine, 1981