Neutral Loss-Based Phosphopeptide Recognition: A Collection of Caveats
- 15 June 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 6 (7) , 2866-2873
- https://doi.org/10.1021/pr060573w
Abstract
The standard strategy for analysis by tandem mass spectrometry of protein phosphorylation at serine or threonine utilizes the neutral loss of H3PO4 (= 97.977/z) from proteolytic peptide molecular ions as marker fragmentation. Manual control of automatically performed neutral loss-based phosphopeptide identifications is strongly recommended, since these data may contain false-positive results. These are connected to the experimental neutral loss m/z error, to competing peptide fragmentation pathways, to limitations in data interpretation software, and to the general growth of protein sequence databases. The fragmentation-related limitations of the neutral loss approach cover (i) the occurrence of abundant 'close-to-98/z' neutral loss fragmentations, (ii) the erroneous assignment of a neutral loss other than loss of H3PO4 due to charge state mix-up, and (iii) the accidental occurrence of any fragment ion in the m/z windows of interest in combination with a charge-state mix-up. The 'close-to-98/z' losses comprise loss of proline (97.053/z), valine (99.068/z), threonine (101.048/z), or cysteine (103.009/z) preferably from peptides with N-terminal sequences PP, VP, TP, or CP, and loss of 105.025/z from alkylated methionine. Confusion with other neutral losses may occur, when their m/z window coincides with a 98/z window as result of a charge state mix-up. Neutral loss of sulfenic acid from oxidized methionine originating from a doubly charged precursor (63.998/2 = 31.999) may thus mimic the loss of phosphoric acid from a triply charged phosphopeptide (97.977/3 = 32.659). As a consequence of the large complexity of proteomes, peptide sequence ions may occur in one of the mass windows of H3PO4 loss around 97.977/z. Practical examples for false-positive annotations of phosphopeptides are given for the first two groups of error. The majority of these can be readily recognized using the guidelines presented in this study.Keywords
This publication has 21 references indexed in Scilit:
- Global proteomic profiling of phosphopeptides using electron transfer dissociation tandem mass spectrometryProceedings of the National Academy of Sciences, 2007
- Methionine oxidation in peptides–a source for false positive phosphopeptide identification in neutral loss driven MS3Rapid Communications in Mass Spectrometry, 2006
- PhosTShunter: A Fast and Reliable Tool to Detect Phosphorylated Peptides in Liquid Chromatography Fourier Transform Tandem Mass Spectrometry Data SetsJournal of Proteome Research, 2006
- Phosphatase-Directed Phosphorylation-Site Determination: A Synthesis of Methods for the Detection and Identification of PhosphopeptidesJournal of Proteome Research, 2005
- Iodoacetamide‐alkylated methionine can mimic neutral loss of phosphoric acid from phosphopeptides as exemplified by nano‐electrospray ionization quadrupole time‐of‐flight parent ion scanningRapid Communications in Mass Spectrometry, 2005
- Selective detection of thiosulfate-containing peptides using tandem mass spectrometryRapid Communications in Mass Spectrometry, 2005
- Identification and characterization of phosphorylated proteins in the human pituitaryProteomics, 2004
- Neutral loss of amino acid residues from protonated peptides in collision‐induced dissociation generates N‐ or C‐terminal sequence laddersJournal of Mass Spectrometry, 2003
- Protein PhosphorylationAnnual Review of Biochemistry, 1975
- Polyacrylamide Gel Electrophoresis of Highly Purified Chick InterferonNature, 1967