No functional impairment after Robodoc total hip arthroplasty
- 1 January 2002
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 73 (4) , 386-391
- https://doi.org/10.1080/00016470216316
Abstract
The Robodoc total hip replacement procedure requires a wider exposure of the proximal femur, especially of the greater trochanter, than the standard procedure. Moreover, the leg must be placed in a rigid leg-holder apparatus to obtain fixation in maximal hip adduction and external rotation. This may impair the hip abductors and reduce hip abduction in the mid- and terminal stance phase of the cycle. In this study we compared patients after Robodoc and conventional total hip arthroplasty with three-dimensional gait analysis (VICON System, Oxford Metrics, Oxford, U.K.) to assess the kinematics of the pelvis and hip. 25 patients underwent total hip replacement by means of the Robodoc total hip arthroplasty system, 25 patients were treated with conventional total hip replacement, and 40 healthy volunteers served as controls. None of the patients undergoing total hip replacement, robotic or conventional, obtained normal kinematic gait patterns 6 months after surgery. However, the reduction in hip abduction did not differ significantly in patients undergoing robotic or conventional total hip arthroplasty, which suggests that the robotic procedure did not impair hip abductor function more than the conventional method.Keywords
This publication has 12 references indexed in Scilit:
- Kinetic analysis of the lower limbs during walking: What information can be gained from a three-dimensional model?Published by Elsevier ,2001
- Primary and Revision Total Hip Replacement Using the Robodoc?? SystemClinical Orthopaedics and Related Research, 1998
- Qualitätssteigerung in der präoperativen Planung und intraoperativen Umsetzung durch die Verwendung von computerassistierten Systemen und Operationsrobotern – eine experimentelle UntersuchungDer Chirurg, 1998
- Functional evaluation of hip abductor muscles with use of magnetic resonance imagingJournal of Orthopaedic Research, 1997
- Repeatability of kinematic, kinetic, and electromyographic data in normal adult gaitJournal of Orthopaedic Research, 1989
- Quantitative gait analysis after unilateral or bilateral total knee replacementJournal of Bone and Joint Surgery, 1987
- The significance of the Trendelenburg testThe Journal of Bone and Joint Surgery. British volume, 1985
- Der transgluteale Zugang bei HüftgelenksarthroplastikZeitschrift für Orthopädie und ihre Grenzgebiete, 1984
- Correlations Between Changes in Gait and in Clinical Status After Knee ArthroplastyActa Orthopaedica, 1981
- The Transgluteal Approach to the Hip JointArchives of orthopaedic and trauma surgery, 1979