Four different HPLC methods for analysis of 25-hydroxyvitamin D3 in serum were evaluated with a method based on isotope dilution-mass spectrometry (ID-MS). Method I utilized Sephadex LH-20 chromatography as the only prepurification step. No correlation with the ID-MS method was obtained. Method II utilized Sephadex LH-20 chromatography and a subsequent reversed phase HPLC step as prepurification. The correlation coefficient was 0.99 (regression coefficient 1.2 and intercept -3.9 μg/l). Method III included open silicic acid chromatography and straight phase HPLC as prepurification. The correlation when compared with the ID-MS method was 0.94 (regression coefficient 1.2 and intercept -0.4 μ/l). In method IV Sep-pak C18, chromatography and open silicic acid chromatography were used as prepurification. The correlation coefficient when compared with the ID-MS method was 0.97 (regression coefficient 0.8 and intercept 0.1 μg/l). It is concluded that a single Sephadex LH-20 step is not sufficient as prepurification and that method IV had an accuracy sufficient for its intended use to analyse 25-hydroxyvitamin D3, in serum from cattle.Keywords
This publication has 29 references indexed in Scilit:
- Quantitation of vitamin D and its metabolites and their plasma concentrations in five species of animalsAnalytical Biochemistry, 1981
- Quantitation of the main metabolites of vitamin D in a single serum sample II. Determination by uv-absorption and competitive protein binding assaysClinica Chimica Acta; International Journal of Clinical Chemistry, 1980
- Quantitation of the main metabolites of vitamin D in a single serum sample I. Extraction, separation and purification of metabolitesClinica Chimica Acta; International Journal of Clinical Chemistry, 1980
- [45] Mass fragmentographic assay of 25-hydroxyvitamin D3Published by Elsevier ,1980
- [43] High-performance liquid chromatographic determination of vitamin D and metabolitesPublished by Elsevier ,1980
- Shorter high-performance liquid chromatograpic method for the determination of 25-hydroxycholecalciferol in cow serumJournal of Agricultural and Food Chemistry, 1980
- The determination of the vitamin D metabolites on a single plasma sample: Changes during parturition in dairy cowsArchives of Biochemistry and Biophysics, 1979
- Isolation and quantitation of endogenous vitamin D and its physiologically important metabolites in human plasma by high pressure liquid chromatographyThe Journal of Steroid Biochemistry and Molecular Biology, 1977
- Determination of 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 in human plasma using high-pressure liquid chromatographyAnalytical Biochemistry, 1977
- High-pressure liquid chromatographic method for the determination of 25-hydroxycholecalciferol in cow plasmaAnalytical Biochemistry, 1976