NEUTRON DIFFRACTION MEASUREMENT OF RESIDUAL STRESS FIELDS—THE ANSWER TO THE ENGINEERS’ PRAYER?
- 1 December 1990
- journal article
- research article
- Published by Taylor & Francis in Nondestructive Testing and Evaluation
- Vol. 5 (5-6) , 395-413
- https://doi.org/10.1080/02780899008952981
Abstract
Design and Production Engineers wish to know the magnitude of residual stresses throughout their fabricated components and weldments in order that they can estimate their maximum loading and fatigue life. A small meter placed on the surface of the component, on which one simply dials a position in the sample and the size of the sampling volume and obtains a read-out of the absolute magnitude and direction of the stress averaged over the volume, would do nicely! At the present time neutron diffraction comes closest to this ideal, but falls far short of it. The technique of stress measurement using neutron diffraction is discussed, with its advantages and outstanding problems, and its use in a number of practical cases is described.Keywords
This publication has 5 references indexed in Scilit:
- Effects of Elastic Anisotropy on the Lattice Strains in Polycrystalline Metals and Composites Measured by Neutron DiffractionPublished by Springer Nature ,1989
- Neutron diffraction methods for the study of residual stress fieldsAdvances in Physics, 1985
- The strain distribution in anisotropic polycrystalline aggregates subjected to an external stress fieldPhilosophical Magazine A, 1984
- Quantitative nondestructive measurements of residual stressesCritical Reviews in Solid State and Materials Sciences, 1980