Vessel Wall Damage Caused by Cerebral Protection Devices: Ex Vivo Evaluation in Porcine Carotid Arteries
- 1 May 2005
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 235 (2) , 454-460
- https://doi.org/10.1148/radiol.2352031968
Abstract
To determine the extent of vessel wall damage caused by cerebral protection devices designed for carotid angioplasty by using ex vivo porcine carotid arteries. The local animal experimentation committee did not require its approval for this study. With a benchtop vascular model (flow rate, 470 mL/min; dicrotic pulsatile flow, 76 pulses per minute; pressure, 115/67 mm Hg [mean pressure, 91 mm Hg]) into which 85 porcine internal carotid arteries (ICAs) were inserted, five different protection devices (Angioguard [Cordis/Johnson & Johnson, Miami, Fla], Filterwire EX [Boston Scientific, Natick, Mass], Trap [Microvena, White Bear Lake, Minn], Neuroshield [Abbott Laboratories, Redwood City, Calif], and Percusurge [Abbott Laboratories]) were evaluated. Adverse movement (1 cm up, 2 cm down, and 1 cm up again) of the activated devices (deployed filters or inflated balloons [Percusurge only]) was simulated, and the device was retrieved. For each of these steps (deployment, movement, retrieval) the amount of debris from the vessel wall in the effluent of the ICA was determined by using a 100-microm filter. The Mann-Whitney test was used to test for differences, and a correction for multiple comparisons was made. P < .05 was considered to indicate a significant difference. The authors attempted to determine whether there was a notable association between the total amount of debris captured and the classification of damage at microscopy. Carotid arteries were analyzed histologically with light and scanning electron microscopy. All examined protection devices caused dislodged debris, which was captured in the effluent filter. There were significant differences among the devices in terms of the total amount of debris captured in the filters (lowest amounts of debris, 4.75 mg [Angioguard] and 5.02 mg [Filterwire EX]; highest amount, 7.51 mg [Trap]; P < or = .001 for all). All devices caused histologically visible wall damage, with the degree of intimal denudation correlating with the mass of the debris. The Trap device caused the most severe intimal and subintimal wall damage. Adverse movement resulted in no increased debris dislodgment as compared with the debris dislodged during deployment and retrieval of the devices. On the basis of the data obtained, cerebral protection devices themselves have a potential influence on embolization rates by causing debris to be dislodged during carotid stent placement.Keywords
This publication has 6 references indexed in Scilit:
- Comparison of Various Cerebral Protection Devices Used for Carotid Artery Stent Placement: An In Vitro ExperimentJournal of Vascular and Interventional Radiology, 2003
- Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection DevicesStroke, 2003
- In Vitro Comparison of Four Cerebral Protection Filters for Preventing Human Plaque Embolization During Carotid InterventionsJournal of Endovascular Therapy, 2002
- Comparison and Modification of Two Cerebral Protection Devices Used for Carotid Angioplasty: In Vitro ExperimentRadiology, 2002
- Embolic risk of the different stages of carotid bifurcation balloon angioplasty: An experimental studyJournal of Vascular Surgery, 2000
- Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysisJournal of Vascular Surgery, 1999