A replicator method for the combined determination of minimum inhibitory concentration and minimum bactericidal concentration
- 1 January 1985
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 15 (1) , 53-60
- https://doi.org/10.1093/jac/15.1.53
Abstract
Minimal bactericidal concentrations (MBCs) of nine antimicrobial agents were determined for clinical isolates by a replica plating method. Membranes were placed on the antibiotic-containing plates and the organisms replicated onto the membranes. After 18 h incubation the minimal inhibitory concentrations (MICs) ere determined, the membranes were transferred to antibiotic-free plates and incubated a further 18 h and the MBCs determined. MICs and MBCs were also determined in broth. The reproducibility of the 'membrane' method and the agreement of these results for MIC and MBC with the agar and/or broth methods was atisfactory for most antibiotics, within one two-fold dilution. With sulphamethoxazole, tnmethoprim and co-trimoxazole the results were less satisfactory, especially with Gram-negative rods, but agreement within two dilutions could be achieved.Keywords
This publication has 5 references indexed in Scilit:
- Method of reliable determination of minimal lethal antibiotic concentrationsAntimicrobial Agents and Chemotherapy, 1980
- Tolerance in Staphylococcus aureus: Evidence for Bacteriophage RoleThe Journal of Infectious Diseases, 1980
- Screening for transferable antibiotic resistance in the clinical laboratoryJournal of Antimicrobial Chemotherapy, 1979
- In-VitroMethods for Determining Minimal Lethal Concentrations of Antimicrobial AgentsAmerican Journal of Clinical Pathology, 1979
- Quantitative Assessment of Bactericidal Activities of β-Lactam Antibiotics by Agar Plate MethodAntimicrobial Agents and Chemotherapy, 1978