Intracoronary γ-Radiation Therapy After Angioplasty Inhibits Recurrence in Patients With In-Stent Restenosis
Top Cited Papers
- 9 May 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 101 (18) , 2165-2171
- https://doi.org/10.1161/01.cir.101.18.2165
Abstract
Background—Treatment of in-stent restenosis presents a critical limitation of intracoronary stent implantation. Ionizing radiation has been shown to decrease neointimal formation within stents in animal models and in initial clinical trials. We studied the effects of intracoronary γ-radiation therapy versus placebo on the clinical and angiographic outcomes of patients with in-stent restenosis. Methods and Results—One hundred thirty patients with in-stent restenosis underwent successful coronary intervention and were then blindly randomized to receive either intracoronary γ-radiation with 192Ir (15 Gy) or placebo. Four independent core laboratories blinded to the treatment protocol analyzed the angiographic and intravascular ultrasound end points of restenosis. Procedural success and in-hospital and 30-day complications were similar among the groups. At 6 months, patients assigned to radiation therapy required less target lesion revascularization and target vessel revascularization (9 [13.8%] and 17 [26.2%...Keywords
This publication has 10 references indexed in Scilit:
- Mechanisms of restenosis and redilation within coronary stents—Quantitative angiographic assessmentPublished by Elsevier ,2010
- Rotational atherectomy for in-stent restenosis: acute and long-term results of the first 100 casesJournal of the American College of Cardiology, 1998
- Predictors of Restenosis After Coronary Stent ImplantationJournal of the American College of Cardiology, 1998
- Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary StentingNew England Journal of Medicine, 1997
- Mechanisms and Results of Balloon Angioplasty for the Treatment of In-Stent RestenosisThe American Journal of Cardiology, 1996
- Intracoronary Radiation Before Stent Implantation Inhibits Neointima Formation in Stented Porcine Coronary ArteriesCirculation, 1995
- Small stent size and intimal hyperplasia contribute to restenosis: A volumetric intravascular ultrasound analysisJournal of the American College of Cardiology, 1995
- Endovascular Low-Dose Irradiation Inhibits Neointima Formation After Coronary Artery Balloon Injury in SwineCirculation, 1995
- Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine modelJournal of the American College of Cardiology, 1994
- Management of restenosis within the Palmaz-Schatz coronary stent (the U.S. multicenter experience)The American Journal of Cardiology, 1993