Assessment of the trackability, flexibility, and conformability of coronary stents: A comparative analysis
- 25 July 2003
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 59 (4) , 496-503
- https://doi.org/10.1002/ccd.10583
Abstract
The efficacy and safety of coronary stent implantation depend on the mechanical features of these devices when deployed in atheromatous lesions of various morphologies. We evaluated the trackability, flexibility, and conformability of 17 coronary stents using specific mechanical bench tests. The quantifications used a dynamometer for assessment of trackability (maximal strength) and flexibility (stiffness) and a 3D optical gauging machine for assessment of conformability (distance between stent and arterial wall in a curvature). The maximal strength (measuring the trackability) ranged respectively from 0.24 +/- 0.06 and 0.38 +/- 0.03 N (Seaquest) to 1.31 +/- 0.42 and 1.34 +/- 0.35 N (Carbostent), concerning respectively curvatures of 90 degrees (P < 0.0001) and 135 degrees (P < 0.0001). The stiffness (measuring the flexibility) ranged from 0.53 +/- 0.16 (Seaquest) to 1.28 +/- 0.10 N/mm (NIR Royal; P < 0.0001). The mean distance between stent and external curvature (external conformability) ranged from 0.15 +/- 0.06 mm (S7) to 0.57 +/- 0.4 mm (NIR Royal; P < 0.0001). The mean distance between stent and internal curve (internal conformability) ranged from 0.26 +/- 0.13 (S7) to 0.44 +/- 0.12 mm (S670; P < 0.0001). These results may influence the choice of a particular stent adapted to a specific coronary anatomy.Keywords
This publication has 8 references indexed in Scilit:
- A Randomized Comparison of a Sirolimus-Eluting Stent with a Standard Stent for Coronary RevascularizationNew England Journal of Medicine, 2002
- Elastic recoil of coronary stents: A comparative analysisCatheterization and Cardiovascular Interventions, 2000
- Radial force of coronary stents: A comparative analysisCatheterization and Cardiovascular Interventions, 1999
- Direct stent implantation without predilatation using the multilink stentThe American Journal of Cardiology, 1998
- Evaluation of the compressive mechanical properties of endoluminal metal stentsCatheterization and Cardiovascular Diagnosis, 1998
- Direct coronary stenting without predilatation: A new therapeutic approach with a special balloon catheter designCatheterization and Cardiovascular Diagnosis, 1998
- Stent Collapse Resistance to External Pressure: Comparison Between Coil and Slotted Tube Stent DesignsJournal of the American College of Cardiology, 1998
- Recommendations on stent manufacture, implantation and utilizationEuropean Heart Journal, 1997