Abstract
RF current density imaging (RF‐CDI) is a new MRI technique for imaging the Larmor frequency current density parallel to B0 in electrolytic media. To extend the use of RF‐CDI to biological tissue for generating conductivity contrast, the sensitivity must be increased and the data requirements reduced. A rotating frame approach, in which a large B1 field is applied simultaneously as a rotary echo with RF current, is proposed to meet these requirements. Rotating frame magnetic fields are encoded in the phase of an MRI image. Trials have now been performed with this sequence in a three‐compartment cylindrical phantom containing doped water or mineral oil for detecting displacement, conduction and fringe field currents. In a postmortem rat study, 85.56 MHz RF currents injected by implanted electrodes created tissue dependent contrast because of the electrical properties of tissue. A sensitivity and artifact analysis was also performed. The sensitivity of this method is determined by the maximum RF pulse duration. SAR limits pose an upper bound on this time and B1, whereas the avoidance of phase artifacts imposes a lower bound on B1.Keywords
This publication has 22 references indexed in Scilit:
- Sensitivity of magnetic-resonance current-density imagingJournal of Magnetic Resonance (1969), 1992
- Phase-modulated rotating-frame spectroscopic localization using an adiabatic plane-rotation pulse and a single surface coilJournal of Magnetic Resonance (1969), 1991
- Measurement of nonuniform current density by magnetic resonanceIEEE Transactions on Medical Imaging, 1991
- The techniques of rotating frame selective excitation and some experimental resultsJournal of Magnetic Resonance (1969), 1988
- Effect of pulse angle imperfection and resonance offset in the phase-modulated rotating-frame spectroscopic imaging experimentJournal of Magnetic Resonance (1969), 1988
- Frequency response of soft pulsesJournal of Magnetic Resonance (1969), 1987
- Amplitude- and frequency-modulated pulses to achieve 90° plane rotations with inhomogeneous B1 fieldsJournal of Magnetic Resonance (1969), 1987
- Detection of residual Z magnetization, with application to the surface coil rotating frame experimentJournal of Magnetic Resonance (1969), 1987
- Estimating radiofrequency power deposition in body NMR imagingMagnetic Resonance in Medicine, 1985
- Rotating frame zeugmatographyJournal of Magnetic Resonance (1969), 1979