Quality Control during Endovascular Aneurysm Repair: Monitoring Aneurysmal Sac Pressure and Superficial Femoral Artery Flow Velocity
- 1 August 1999
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 6 (3) , 239-245
- https://doi.org/10.1177/152660289900600305
Abstract
Purpose: To use intraoperative aneurysmal sac pressure measurement and flow monitoring of the superficial femoral artery (SFA) to ensure complete exclusion of the aneurysm from the circulation. Methods: A 5F catheter was positioned in the aneurysmal sac of 15 consecutive patients undergoing endovascular aortomonoiliac aneurysm repair between February and September 1997. The catheter was connected to an external pressure transducer allowing pressure monitoring throughout the operation and for 24 hours postprocedurally. Flow velocity was monitored in the contralateral SFA by insonation with a 2-MHz Doppler ultrasound probe. Results: No technical defect was observed in the deployment of 10 endografts, which demonstrated marked reduction in sac pressure and good flow in the lower limb. The mean aneurysm pressure dropped from 123 to 57 mmHg after graft insertion. In 5 cases, monitoring detected problems during the endograft procedure. In 3, incomplete stent deployment was detected by a failure of sac pressure to fall following stent inflation and by the presence of flow in the contralateral femoral artery. In the other 2 cases, a distal endoleak was detected by direct injection of contrast into the sac. Conclusions: Measuring aneurysm pressure in combination with SFA Doppler flow monitoring can detect complications of endovascular aneurysm repair.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of computed tomography and duplex imaging in assessing aortic morphology following endovascular aneurysm repairBritish Journal of Surgery, 1998
- Aortomonoiliac Endovascular Grafting: Difficult Solutions to Difficult AneurysmsJournal of Endovascular Therapy, 1997
- Endoleak as a Complication of Endoluminal Grafting of Abdominal Aortic Aneurysms: Classification, Incidence, Diagnosis, and ManagementJournal of Endovascular Therapy, 1997
- Endovascular Treatment of Abdominal Aortic Aneurysms: Lessons LearnedJournal of Endovascular Therapy, 1997
- Microembolization during endovascular and conventional aneurysm repairJournal of Vascular Surgery, 1997
- Aneurysm pressure following endovascular exclusionEuropean Journal of Vascular and Endovascular Surgery, 1997
- Endovascular repair of abdominal aortic aneurysm: An initial experienceBritish Journal of Surgery, 1996
- A Prospective Study of Changes in Morphology and Dimensions of Abdominal Aortic Aneurysms following Endoluminal Repair: A Preliminary ReportJournal of Endovascular Therapy, 1995
- An aortic aneurysm model for the evaluation of endovascular exclusion prosthesesJournal of Vascular Surgery, 1995