Pulse contour analysis versus thermodilution in cardiac surgery patients
- 19 April 2002
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 46 (4) , 424-429
- https://doi.org/10.1034/j.1399-6576.2002.460416.x
Abstract
Background: Previous studies have demonstrated that there is a lack of agreement between intermittent cold bolus thermodilution (ICO) and a semicontinuous method with dilution of heat (CCO) in cardiac surgical patients following hypothermic extracorporeal circulation (HCPB). Therefore, the aim of the present study was to compare both ICO and CCO with continuous pulse contour analysis (PCCO): a method based on a fundamentally different principle of determining cardiac output (CO). Methods: A prospective criterion standard study of 25 cardiac surgery patients undergoing HCPB. Cardiac output was determined using the three methods (ICO, CCO, and PCCO) before and after HCPB up to 12 h after arrival on the ICU. Bias and precision were evaluated. Results: A total of 380 triple determinations of CO could be analyzed. During the entire study period bias PCCO‐ICO was −0.14 l*/min (precision 1.16 l*/min) and bias CCO‐ICO was −0.40 l*/min (precision 1.25 l*/min). Up to 45 min after bypass PCCO agreed with ICO (bias −0.21 l*/min, precision 1.37 l*/min), while bias CCO‐ICO was −1.30 l*/min (precision 1.45 l*/min). Conclusion: The agreement between PCCO and ICO in contrast to CCO in the first 45 min after HCPB indicates that CCO underestimates CO during this period.Keywords
This publication has 26 references indexed in Scilit:
- Continuous Cardiac Output Monitoring During Adult Liver TransplantationAnesthesia & Analgesia, 1997
- Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantationAnaesthesia, 1997
- Ventilation, Thermal Noise, and Errors in Cardiac Output Measurements after Cardiopulmonary BypassAnesthesiology, 1993
- Errors in the measurement of cardiac output by thermodilutionCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1993
- Continuous Cardiac Output by ThermodilutionInternational Anesthesiology Clinics, 1993
- Errors in Thermodilution Cardiac Output Measurements Caused by Rapid Pulmonary Artery Temperature Decreases after Cardiopulmonary BypassAnesthesiology, 1992
- Continuous measurement of cardiac output by the Fick principleCritical Care Medicine, 1992
- Continuous measurement of cardiac output with the use of stochastic system identification techniquesJournal of Clinical Monitoring and Computing, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Measurement of Cardiac Stroke Volume During Cesarean Section: A Comparison Between Impedance Cardiography and the Dye Dilution TechniqueActa Anaesthesiologica Scandinavica, 1983