The Orthotic Effect of Functional Electrical Stimulation on the Improvement of Walking in Stroke Patients with a Dropped Foot: A Systematic Review
- 20 May 2004
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 28 (6) , 577-586
- https://doi.org/10.1111/j.1525-1594.2004.07310.x
Abstract
Analysis of the available evidence on the improvement of walking in stroke patients with a dropped foot when using peroneus stimulation. A systematic review was performed to identify trials that investigated the orthotic effect of functional electrical stimulation (FES) on walking in stroke patients with a dropped foot. Two independent raters scored the methodological quality of the included articles. Walking speed and physiological cost index (PCI) were selected as the primary outcome measures. Studies that measured walking speed were pooled and a pooled difference including confidence interval was calculated. Eight studies were included in the review, of which one was a randomized controlled trial. Methodological score ranged from 8 to 18 out of 19. Six studies measured walking speed. The pooled improvement in walking speed was 0.13 m/s (0.07-0.2) or 38% (22.18-53.8). The present review suggests a positive orthotic effect of functional electrical stimulation on walking speed.Keywords
This publication has 35 references indexed in Scilit:
- A review of portable FES-based neural orthoses for the correction of drop footIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2002
- DiscussionJournal of Clinical Epidemiology, 1999
- Functional electrical stimulation: a review of the literature published on common peroneal nerve stimulation for the correction of dropped footReviews in Clinical Gerontology, 1998
- Experience of Clinical Use of the Odstock DroppedFoot StimulatorArtificial Organs, 1997
- Functional electrostimulation in poststroke rehabilitation: A meta-analysis of the randomized controlled trialsArchives of Physical Medicine and Rehabilitation, 1996
- Classification of Walking Handicap in the Stroke PopulationStroke, 1995
- Implantable stimulator for selective stimulation of the common peroneal nerve: a preliminary reportJournal of Medical Engineering & Technology, 1994
- Application of a programmable dual-channel adaptive electrical stimulation system for the control and analysis of gaitJournal of Rehabilitation Research and Development, 1992
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986
- Current problems and future challenges in randomized clinical trials.Circulation, 1984