Automated On-Line Isotope Dilution Analysis with ICP-MS Using Sandwich Flow Injection
- 3 February 1998
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 70 (5) , 1036-1040
- https://doi.org/10.1021/ac9710691
Abstract
An automated flow injection (FI) manifold is described to perform the addition of isotopic spikes to aqueous samples on-line with ICP-MS for isotope dilution (ID) analysis. The manifold uses the sandwich technique (with the nested loop approach) to perform an injection of the isotopic spike solution within a sample (or standard) plug, the resulting sample−spike−sample sequence being pushed toward the nebulizer by a 1% HNO3 carrier. A standard, which must contain one element not present in the spike solution to allow the determination of the dispersion coefficient, must also be used to allow a reverse isotope dilution analysis, as well as corrections for mass discrimination and/or spectroscopic interferences. Indeed, because the signals from the individual isotopes are monitored continuously, only one isotope free of spectroscopic interference is required for elements whose isotopic distribution does not vary in nature (two isotopes are still needed for the other elements), as a correction for the interference can be made by comparison with the signals from the standard. Furthermore, this automated approach makes ID-ICP-MS a faster method and does not require any preliminary analysis of the sample because the concentration profile resulting from FI allows the selection of the best isotopic ratio. It was successfully applied to the determination of Mo in saline water.Keywords
This publication has 10 references indexed in Scilit:
- On-Line Isotope Dilution Analysis with ICPMS Using Reverse Flow InjectionAnalytical Chemistry, 1997
- SI-traceable values for cadmium and lead concentration in the candidate reference material, MURST-ISS A1 Antarctic sediment, by combination of ICP-MS with isotope dilutionAnalytica Chimica Acta, 1997
- Chromatographic Isolation of Molybdenum From Human Blood Plasma and Determination by Inductively Coupled Plasma Mass Spectrometry With Isotope DilutionJournal of Analytical Atomic Spectrometry, 1997
- Certification of the Rubidium Concentration in Water Materials for the International Measurement Evaluation Programme (IMEP) Using Isotope Dilution Inductively Coupled Plasma Mass SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- A theoretical adaptation of the classical isotope dilution technique for practical routine analytical determinations by means of inductively coupled plasma mass spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Flow injection sandwich technique applied to indirect visible spectrophotometric determinations. bromimetric and iodimetric determination of sulphiteAnalytica Chimica Acta, 1995
- The determination of lead in blood using isotope dilution inductively coupled plasma mass spectrometryAnalytical and Bioanalytical Chemistry, 1995
- Selenium, chromium and zinc content of proposed SRM 1846 infant formulaAnalytical and Bioanalytical Chemistry, 1995
- Application of isotope dilution analysis—inductively coupled plasma mass spectrometry to the precise determination of silver and antimony in pure copperJournal of Analytical Atomic Spectrometry, 1992
- Sandwich standardization in flow-injection analysisTalanta, 1989