Variability in Measurement of Extracranial Internal Carotid Artery Stenosis as Displayed by Both Digital Subtraction and Magnetic Resonance Angiography
- 1 March 1996
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 27 (3) , 467-473
- https://doi.org/10.1161/01.str.27.3.467
Abstract
Background and Purpose The degree of stenosis in the extracranial internal carotid artery helps predict the risk of an individual suffering subsequent cerebrovascular ischemic events. Different techniques have evolved to measure stenosis from angiograms, leading to some confusion and a call for the adoption of a single technique. To help choose the most reliable technique, this study assessed observer variability in reporting carotid stenosis for four different techniques, from both digital subtraction (DSA) and MR angiograms (MRA). Three of the techniques used caliper measurements; the fourth was the visual impression of stenosis. Methods From a total of 137 angiograms, caliper measurements were possible on 105 DSAs and 74 MRAs. Measurements from these angiograms were made by two independent observers on two separate occasions to assess interobserver and intraobserver variation in reporting. Results For DSA, the variability in reporting and the number of clinically significant differences arising as a result were similar for each of the four techniques. While the typical measurement errors for each of the techniques studied were on the order of ±5%, each technique produced some sizable individual differences for the same angiogram, with resultant wide 95% limits of agreement. Observer variability for reporting MRA was generally a little greater than for DSA. Compared with the caliper techniques, the visual impression of stenosis technique performed well, particularly for MRA. Conclusions Although observer variability in reporting can be considerable, no important differences were found among the different techniques widely used for measuring carotid stenosis.Keywords
This publication has 6 references indexed in Scilit:
- Comparison of magnetic resonance angiography, duplex ultrasound, and digital subtraction angiography in assessment of extracranial internal carotid artery stenosis.Journal of Neurology, Neurosurgery & Psychiatry, 1994
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991
- MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosisThe Lancet, 1991
- Quantitative computer techniques for analyzing coronary arteriogramsProgress in Cardiovascular Diseases, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960