Multislice first‐pass cardiac perfusion MRI: Validation in a model of myocardial infarction†
- 20 February 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (3) , 482-491
- https://doi.org/10.1002/mrm.10085
Abstract
The purpose of this study was to validate a first‐pass MRI method for imaging myocardial perfusion with multislice coverage and relatively small analyzable regions of interest (ROIs). A fast gradient‐echo (FGRE) sequence with an echo‐train (ET) readout was used to achieve multislice coverage, and a high dose of a contrast agent (CA) was used to achieve a high signal‐to‐noise ratio (SNR). Dogs (N = 6) were studied 1 day after reperfused myocardial infarction, and fluorescent microspheres were used as a standard for perfusion. First‐pass MRI correlated well vs. microsphere flow, achieving mean R values of 0.87 (range = 0.82–0.93), 0.71 (range = 0.46–0.85), and 0.72 (range = 0.49–0.95) for subendocardial ROIs, transmural ROIs, and the endocardial‐epicardial ratio, respectively. Additionally, analysis of myocardial time‐intensity curves (TICs) indicated that 15.8 ± 6.6° sectors, corresponding to 260 μl of endocardium, can be analyzed (R2 > 0.95). Magn Reson Med 47:482–491, 2002. Published 2002 Wiley‐Liss, Inc.Keywords
This publication has 25 references indexed in Scilit:
- Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac functionJournal of Magnetic Resonance Imaging, 1999
- Myocardial perfusion and function in dogs with moderate coronary stenosisMagnetic Resonance in Medicine, 1996
- Technical note—Approach to myocardial perfusion with echo planar imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 1996
- Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparationMagnetic Resonance in Medicine, 1995
- Influence of bolus volume and dose of gadolinium chelate for first‐pass myocardial perfusion MR imaging studiesJournal of Magnetic Resonance Imaging, 1995
- Multislice first‐pass myocardial perfusion imaging on a conventional clinical scannerMagnetic Resonance in Medicine, 1995
- Inversion recovery EPI of bolus transit in rat myocardium using intravascular and extravascular gadolinium‐based MR contrast media: Dose effects on peak signal enhancementMagnetic Resonance in Medicine, 1994
- Ischemic heart disease: Assessment with gadolinium‐enhanced ultrafast MR imaging and dipyridamole stressJournal of Magnetic Resonance Imaging, 1994
- Contrast‐enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemiaMagnetic Resonance in Medicine, 1993
- Effect of volume and rate of contrast medium injection on intravenous digital subtraction angiographic contrast medium curvesJournal of the American College of Cardiology, 1984