Addition of tertiary amines in the semiquantitative, multi-element inductively coupled plasma mass spectrometric analysis of biological materials
- 1 January 1996
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 11 (5) , 343-352
- https://doi.org/10.1039/ja9961100343
Abstract
A semiquantitative inductively coupled plasma mass spectrometric (ICP-MS) analysis protocol for biological materials was developed to include water-soluble tertiary amines with microwave heated sample preparation. Certified reference materials digested with HNO3, H2O2 and HF required addition of H3BO3 and a solution of tertiary amines (CFA-C reagent) to dissolve insoluble fluorides and neutralize free fluorides. Commercial semiquantitative analysis software that evaluates the entire m/z range and includes pre-programmed corrections for spectroscopic interferences was applied to investigate matrix interferences resulting from 10% tertiary amines and chlorides (added as 1% HCl). Measurement parameters including m/z range, spectrometer sensitivity and number of elements in the external calibration were evaluated. The accuracy of the semiquantitative analysis improved when the standard solution was matrix matched; interference-free isotopes were selected for some elements instead of scanning the whole m/z range, and additional elements with m/z values of under 80 were included for updating the instrument pre-calibration response factor. This semiquantitative analysis approach can be applied successfully for the multi-element analysis of biological materials when optimum instrumental conditions are employed. Thirty-eight elements were determined in six certified reference materials and food samples with a precision of 1–20% and accuracy of 1–50%. The determinations of Al, K, Na and Si were unreliable.Keywords
This publication has 29 references indexed in Scilit:
- Microwave digestion for the determination of arsenic, cadmium and lead in seafood products by inductively coupled plasma atomic emission and mass spectrometryThe Analyst, 1994
- Determination of low silicon concentrations in food and coral soil by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Reduction of matrix effects and mass discrimination in inductively coupled plasma mass spectrometry with optimized argon–nitrogen plasmasJournal of Analytical Atomic Spectrometry, 1994
- Spectral interferences encountered in the analysis of biological materials by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Inductively coupled plasma atomic emission spectrometric determination of aluminium, barium, silicon, strontium and titanium in food after sample fusionThe Analyst, 1994
- Elimination of interferences in the determination of arsenic and selenium in biological samples by inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1993
- Inductively coupled plasma mass spectrometry of biological samples. Invited lectureJournal of Analytical Atomic Spectrometry, 1993
- Comparison of sample decomposition procedures for the determination of zinc in milk by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1992
- Multi-element analysis of biological tissues by inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1991
- Inductively coupled plasma spectrometry in the study of childhood soil ingestion. Part 1. MethodologyJournal of Analytical Atomic Spectrometry, 1989