Effect of femoral head size on wear of the polyethylene acetabular component.
- 1 April 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 72 (4) , 518-528
- https://doi.org/10.2106/00004623-199072040-00008
Abstract
A technique was developed to determine the wear of the acetabular component of a total hip replacement by examination of standardized initial and follow-up radiographs. Three hundred and eighty-five hips were followed for at least 9.5 years after replacement. The least amount and rate of linear wear were associated with use of a femoral head that had a diameter of twenty-eight millimeters (p less than 0.001). The greatest amount and mean rate of linear wear occurred with twenty-two-millimeter components, but these differences were not statistically significant. The greatest volumetric wear and mean rate rate of volumetric wear were seen with thirty-two-millimeter components (p less than 0.001). A wider radiolucent line in acetabular Zone 1 was associated with use of the thirty-two-millimeter head. The amounts of resorption of the proximal part of the femoral neck and of lysis of the proximal part of the femur both correlated positively with the extent of linear and volumetric wear; this suggests an association between the amount of debris from wear and these changes in the femoral neck and proximal part of the femur.Keywords
This publication has 11 references indexed in Scilit:
- The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.Journal of Bone and Joint Surgery, 1986
- Localized osteolysis in stable, non-septic total hip replacement.Journal of Bone and Joint Surgery, 1986
- Dislocations after total hip arthroplasty.Journal of Bone and Joint Surgery, 1982
- Ten-year follow-up study of total hip replacement.Journal of Bone and Joint Surgery, 1982
- Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening deviceJournal of Biomedical Materials Research, 1981
- A ten-year follow-up study of our first one hundred consecutive Charnley total hip replacements.Journal of Bone and Joint Surgery, 1981
- On the true wear rate of ultra high-molecular-weight polyethylene in the total hip prosthesis.Journal of Bone and Joint Surgery, 1980
- The appearances of wear on polyethylene—a comparison of in vivo and in vitro wear surfacesJournal of Biomedical Materials Research, 1978
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977