Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.
Open Access
- 1 April 1988
- Vol. 59 (4) , 419-428
- https://doi.org/10.1136/hrt.59.4.419
Abstract
Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one patient; the decreases in patients with single vessel or multivessel disease were similar. The fall in left ventricular ejection fraction during percutaneous transluminal coronary angioplasty of the left anterior descending artery (19%) was significantly greater than that during balloon inflation in the right coronary (10%) or circumflex (8%) coronary arteries. It also reduced anterobasal, anterior, and apical segmental shortening while right coronary percutaneous transluminal coronary angioplasty affected inferior and apical segments. In 33 (63%) patients the ST segment was altered during balloon inflation. The fall in left ventricular ejection fraction correlated significantly with the magnitude of both ST segment elevation (r = 0.637) and ST depression (r = 0.396). Left ventricular ejection fraction and regional wall motion returned to baseline values after the procedure. Balloon inflation during percutaneous transluminal coronary angioplasty produces considerable abnormalities of global and regional left ventricular performance and this indicates the presence of myocardial ischaemia, which may not be apparent on electrocardiographic monitoring. Intravenous digital subtraction ventriculography is useful for monitoring left ventricular performance during controlled episodes of coronary occlusion produced by balloon inflation.This publication has 22 references indexed in Scilit:
- Two-dimensional echocardiography during percutaneous transluminal coronary angioplastyAmerican Heart Journal, 1986
- Echocardiographic evaluation of left ventricular function during coronary artery angioplastyThe American Journal of Cardiology, 1986
- Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplastyJournal of the American College of Cardiology, 1985
- Left ventricular performance, regional blood flow, wall motion, and lactate metabolism during transluminal angioplasty.Circulation, 1984
- Evaluation of left ventricular contractile pattern by intravenous digital subtraction ventriculography: Comparison with cineangiography and assessment of interobserver variabilityThe American Journal of Cardiology, 1983
- Evaluation of left ventricular performance using digital subtraction angiographyThe American Journal of Cardiology, 1983
- The stunned myocardium: prolonged, postischemic ventricular dysfunction.Circulation, 1982
- Left ventricular imaging with digital subtraction angiography using intravenous contrast injection and fluoroscopic exposure levelsAmerican Heart Journal, 1982
- T. Duckett Jones Memorial Lecture. The Jones criteria and the challenges of clinimetrics.Circulation, 1982
- The use of single plane angiocardiograms for the calculation of left ventricular volume in manAmerican Heart Journal, 1968