Liquid Chromatographic Determination of Naproxen and Related Compounds in Raw Materials

Abstract
A liquid chromatographic (LC) method for determination of naproxen and 8 known related compounds has been developed. The lower limit of quantitation of the related compounds In the drug Is 0.04% or less for all compounds; the precision of the drug assay method Is ca 0.4%. The method uses an octadecylsllyl column, a mobile phase of 1 % acetic acid (v/v)-methanol-acetonitrlle (48 + 22 + 30, v/v/v) and detection at 231 nm.

This publication has 0 references indexed in Scilit: