PET Measurement of Regional Lung Density
- 1 September 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 10 (5) , 723-729
- https://doi.org/10.1097/00004728-198609000-00002
Abstract
Regional lung density (LD) and lung water (LW) measurements were made with positron transmission and emission tomography (PET) in normal and edematous lung in supine dogs in vivo. A comparison was also made of LD mesurements by PET and X-ray CT (used by others to noninvasively assess pulmonary edema). Mean LW was 0.25 .+-. 0.06 ml water/ml lung and the mean LD (PET) was 0.32 .+-. 0.06 g/ml lung (average ratio of LW to LD was 0.795 .+-. 0.041). The LD measurements ranged from 0.25 .+-. 0.06 in anterior portions of lung to 0.43 .+-. 0.11 g/ml in posterior areas, but the ratio of LW to LD was similar throughout the lung. The LW and LD measurements obtained in both normal and edematous portions of lung were strongly correlated (r = 0.886). Values for LD by PET were consistently higher than values obtained for LD by X-ray CT. These differences are probably due to beam-hardening effects with CT and partial-volume averaging and scattered radiation effects with PET. Nevertheless, PET-LD measurements may be a satisfatory method for following acute changes in LW or for normalizing other PET-derived data.This publication has 12 references indexed in Scilit:
- Pulmonary density distribution in experimental and clinical cardiogenic pulmonary edema evaluated by computed transmission tomographyAmerican Heart Journal, 1984
- Quantification of regional extravascular lung water in dogs with positron emission tomography, using constant infusion of 15O-labeled waterEuropean Journal of Nuclear Medicine and Molecular Imaging, 1984
- Regional extravascular density and fractional blood volume of the lung in interstitial disease.Thorax, 1984
- PULMONARY DENSITY DISTRIBUTION IN EXPERIMENTAL NONCARDIAC CANINE PULMONARY-EDEMA EVALUATED BY COMPUTED TRANSMISSION TOMOGRAPHY1984
- CT-number variability in thoracic geometryAmerican Journal of Roentgenology, 1983
- Pulmonary EdemaJournal of Computer Assisted Tomography, 1982
- The unreliability of CT numbers as absolute valuesAmerican Journal of Roentgenology, 1982
- Quantitative Measurement of Regional Extravascular Lung Density Using Positron Emission and Transmission TomographyJournal of Computer Assisted Tomography, 1981
- Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical EffectsJournal of Computer Assisted Tomography, 1981
- Measurement of Pulmonary EdemaCirculation Research, 1965