Voltammetric Detection of Heparin at Polarized Blood Plasma/1,2-Dichloroethane Interfaces
- 9 August 2005
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (17) , 5711-5719
- https://doi.org/10.1021/ac050833d
Abstract
Heparin, a highly negatively charged polysaccharide, which has been used widely as an anticoagulant and antithrombotic, was detected by ion-transfer voltammetry at the interface between 1,2-dichloroethane and an aqueous buffer solution or undiluted blood plasma. Quaternary ammoniums with different numbers of methyl and long alkyl groups were examined as positively charged heparin ionophores using pipet electrodes filled with the organic electrolyte solutions of their tetrakis(4-chlorophenyl)borate salts. It was shown that octadecyltrimethylammonium most selectively facilitates interfacial heparin adsorption without interference from potential-dependent ionophore transfer into the aqueous phase. Water-filled pipet electrodes were also used to study the stoichiometry of the interfacial complex between a heparin molecule and multiple ionophore molecules, which is discussed as a counterion condensation effect. Stripping voltammetry based on facilitated heparin adsorption and desorption gives a detection limit of 0.012 unit/mL in 0.12 M NaCl buffered at pH 7.2, which is 1 order of magnitude lower than therapeutic heparin concentrations (>0.2 unit/mL) and is comparable to a detection limit of the most sensitive heparin sensor reported so far. The biomedical utility of ion-transfer voltammetry was demonstrated for the first time in an undiluted blood sample. Despite interferences by Na+, Cl-, and plasma proteins such as serum albumin, a detection limit of 0.13 unit/mL was obtained in sheep blood plasma with the stripping method.Keywords
This publication has 31 references indexed in Scilit:
- Noncovalent Binding between Guanidinium and Anionic Groups: Focus on Biological- and Synthetic-Based Arginine/Guanidinium Interactions with Phosph[on]ate and Sulf[on]ate ResiduesChemical Reviews, 2004
- Evidence for a Diffuse Interfacial Region at the Dichloroethane/Water InterfaceThe Journal of Physical Chemistry B, 2004
- Binding of heparin to plasma proteins and endothelial surfaces is inhibited by covalent linkage to antithrombinThrombosis and Haemostasis, 2004
- Voltammetry of the Phase Transfer of Polypeptide Protamines across Polarized Liquid/Liquid InterfacesJournal of the American Chemical Society, 2003
- Cation Binding to DNA Studied by Ion-Transfer Voltammetry at MicropipetsAnalytical Chemistry, 1998
- Peer Reviewed: Polyion-Sensitive Membrane Electrodes for Biomedical AnalysisAnalytical Chemistry, 1996
- Trace analysis in solution using zeolite-modified electrodesAnalytical Chemistry, 1992
- Bovine serum albumin adsorption on a water/nitrobenzene interfaceBioelectrochemistry and Bioenergetics, 1990
- The Theory of Liquid Ion-exchange Membrane Ion-selective Electrodes Based on the Concept of the Mixed Ion-transfer PotentialBulletin of the Chemical Society of Japan, 1984
- Theory and applications of ion-selective electrodes part 4Analytica Chimica Acta, 1982