Evaluation of the utility of neutral‐loss‐dependent MS3 strategies in large‐scale phosphorylation analysis
- 29 October 2008
- journal article
- research article
- Published by Wiley in Proteomics
- Vol. 8 (21) , 4444-4452
- https://doi.org/10.1002/pmic.200800283
Abstract
Phosphopeptide identification and site determination are major challenges in biomedical MS. Both are affected by frequent and often overwhelming losses of phosphoric acid in ion trap CID fragmentation spectra. These losses are thought to translate into reduced intensities of sequence informative ions and a general decline in the quality of MS/MS spectra. To address this issue, several methods have been proposed, which rely on extended fragmentation schemes including collecting MS3 scans from neutral loss‐containing ions and multi‐stage activation to further fragment these same ions. Here, we have evaluated the utility of these methods in the context of a large‐scale phosphopeptide analysis strategy with current instrumentation capable of accurate precursor mass determination. Remarkably, we found that MS3‐based schemes did not increase the overall number of confidently identified peptides and had only limited value in site localization. We conclude that the collection of MS3 or pseudo‐MS3 scans in large‐scale proteomics studies is not worthwhile when high‐mass accuracy instrumentation is used.Keywords
This publication has 17 references indexed in Scilit:
- Investigating MS2/MS3 Matching StatisticsMolecular & Cellular Proteomics, 2008
- The effects of mass accuracy, data acquisition speed, and search algorithm choice on peptide identification rates in phosphoproteomicsAnalytical and Bioanalytical Chemistry, 2007
- Analysis of phosphorylation sites on proteins from Saccharomyces cerevisiae by electron transfer dissociation (ETD) mass spectrometryProceedings of the National Academy of Sciences, 2007
- Large-scale phosphorylation analysis of mouse liverProceedings of the National Academy of Sciences, 2007
- Global, In Vivo, and Site-Specific Phosphorylation Dynamics in Signaling NetworksCell, 2006
- Electron transfer dissociation of peptide anionsJournal of the American Society for Mass Spectrometry, 2005
- Quantitative Phosphoproteomics Applied to the Yeast Pheromone Signaling PathwayMolecular & Cellular Proteomics, 2005
- Large-scale characterization of HeLa cell nuclear phosphoproteinsProceedings of the National Academy of Sciences, 2004
- A Neutral Loss Activation Method for Improved Phosphopeptide Sequence Analysis by Quadrupole Ion Trap Mass SpectrometryAnalytical Chemistry, 2004
- Novel Linear Quadrupole Ion Trap/FT Mass Spectrometer: Performance Characterization and Use in the Comparative Analysis of Histone H3 Post-translational ModificationsJournal of Proteome Research, 2004