Nebulization and selective deposition of LTD4in human lungs
- 1 July 1987
- Vol. 42 (5) , 336-342
- https://doi.org/10.1111/j.1398-9995.1987.tb02219.x
Abstract
The process of nebulization and deposition of LTD4 was studied in detail. The concentration of LTD4 in a saline solution decreased by approximately 90% after 2 min of nebulization in a DeVilbiss 35B ultrasonic nebulizer. This decrease was prevented by diluting LTD4 in a phosphate buffer, pH 7.4. Nebulization of tritiated LTD4 in this phosphate buffer did not cause any appreciable deterioration of the leukotriene, as demonstrated by an unchanged ratio between radioactivity and LTD4 concentration in the test solution before and after nebulization as well as in the condensed aerosol. The aerosol generated by the DeVilbiss 35B ultrasonic nebulizer was shown to generate particles with a mass median diameter of 1.3 microns (dry particle size). Interposition of a settling bag reduced the amount of large particles, reducing the mass median diameter to 0.84 microns (dry particle size). Nine healthy volunteers were challenged on separate days with 40 nmol LTD4 or 100 .mu.mol histamine, and the changes in FEV1 and partial flow volume curves initiated at 50% of vital capacity (Vmax30) were measured. A relative diffuse deposition pattern was ensured by inhalation via a settling bag. These results were compared to challenges with a relatively central deposition pattern as ensured by inhalation directly from the nebulizer with brisk inhalation maneuvers. The diffuse deposition pattern caused minimal changes in FEV1 but pronounced effect in vmax30. The effects of LTD4 and histamine on FEV1 and Vmax30 changed in parallel when the deposition of the mediators was changed to a more central pattern. This indicates that the two mediators do not differ with respect to any selective effects on different parts of the airways.Keywords
This publication has 20 references indexed in Scilit:
- Decomposition of leukotriene C4Journal of Allergy and Clinical Immunology, 1984
- Physical properties and mechanisms of deposition of aerosolsPublished by Elsevier ,1984
- Measurements of the total and regional deposition of inhaled particles in the human respiratory tractJournal of Aerosol Science, 1982
- Bronchoconstrictor Effects of Leukotriene C in HumansScience, 1982
- Leukotriene C4 affects pulmonary and cardiovascular dynamics in monkeyNature, 1982
- BRONCHOCONSTRICTION PRODUCED IN MAN BY LEUKOTRIENES C AND DThe Lancet, 1981
- Slow-reacting substances (leukotrienes) contract human airway and pulmonary vascular smooth muscle in vitroNature, 1981
- Comparative airway and vascular activities of leukotrienes C-1 and D in vivo and in vitro.Proceedings of the National Academy of Sciences, 1980
- Experimental determination of the regional deposition of aerosol particles in the human respiratory tractAihaj Journal, 1980
- The chronicity of acute attacks of asthma—mechanical and therapeutic implicationsJournal of Allergy and Clinical Immunology, 1975