An Evaluation of a Four-Channel Multiplexed Electrospray Tandem Mass Spectrometry for Higher Throughput Quantitative Analysis
- 16 March 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (8) , 1896-1902
- https://doi.org/10.1021/ac0112014
Abstract
A four-channel multiplexed electrospray inlet system (MUX) coupled to a triple quadrupole mass spectrometer was investigated as a higher throughput approach to quantitative analysis. Four discrete samples may be simultaneously analyzed by virtue of a rotating sampler with a concomitant 4-fold increase in analytical throughput. Although absolute sensitivity was reduced using the MUX interface compared with analysis using traditional single electrospray interface, reproducibility of response was shown to be comparable. Source robustness was established for the analysis of both aqueous drug standards and drugs in biological media, and linearity of response for a test compound, diazepam, was demonstrated over 2 orders of magnitude. Analyte-dependent response differences were exhibited between the four channels of the interface, and this led to the overall conclusion that samples to be compared quantitatively must be analyzed through the same sprayer. In addition, each channel must be independently calibrated to afford true quantification. Should a deuterated internal standard be employed, however, quantitative comparisons can be made across channels. An HPLC pumping system providing individual back-pressure regulation to each channel was shown to provide adequate chromatography even in the event of a channel blockage. Furthermore, following multiple injections of biological samples onto the MUX interface, an eluent flow diversion was integrated into the first part of each analytical run. This served to prevent source fouling, and thus, no detrimental effects to response reproducibility or sensitivity were observed.Keywords
This publication has 16 references indexed in Scilit:
- Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughputRapid Communications in Mass Spectrometry, 2000
- High throughput liquid chromatography/mass spectrometric analyses using a novel multiplexed electrospray interfaceRapid Communications in Mass Spectrometry, 1999
- Determination of Pranlukast and its metabolites in human plasma by LC/MS/MS with PROSPEKTTM on-line solid-phase extractionJournal of Mass Spectrometry, 1998
- High-throughput approaches for evaluating absorption, distribution, metabolism and excretion properties of lead compoundsCurrent Opinion in Chemical Biology, 1998
- New technologies for high-throughput screeningCurrent Opinion in Chemical Biology, 1997
- Simultaneous Pharmacokinetic Screening of a Mixture of Compounds in the Dog Using API LC/MS/MS Analysis for Increased ThroughputJournal of Medicinal Chemistry, 1997
- Applications of Combinatorial Technologies to Drug Discovery. 2. Combinatorial Organic Synthesis, Library Screening Strategies, and Future DirectionsJournal of Medicinal Chemistry, 1994
- Automatic solid-phase extraction and high-performance liquid chromatographic determination of quinidine in plasmaJournal of Chromatography A, 1994
- Applications of Combinatorial Technologies to Drug Discovery. 1. Background and Peptide Combinatorial LibrariesJournal of Medicinal Chemistry, 1994
- On-line solid-phase extraction with automated cartridge exchange for liquid chromatographic determination of lipophilic antioxidants in plasmaJournal of Chromatography A, 1994